4.5 Completion Status
Unified Controller nv Series DeviceNet Module DN611B Instruction Manual
69
4.5
Completion Status
The completion statuses that DN611B returns in response to the requests issued by the controller are shown
below.
Completion status
Code
Description
Normal completion
0001H Indicates a request is completed normally.
Local station failure
00A0H When a request for inhibited processing is issued in down mode
Serial number
unregistered
00A1H A serial number registered in the DN611B disappeared.
Ask for repair because the DN611B needs resetting.
Local station parameters
not set yet
00A2H A request for inhibited processing is issued when local station
parameters have not been set yet.
Length error
00A3H Data size of a bit strobe output data write request is 8 bytes or more.
Station mode error
00A4H A request for inhibited processing is issued during run mode; a
request for inhibited processing is issued during standby mode.
00A5H Reserved
Transmission inhibited
00A6H A request related to transmission is issued by the controller in a state
where transmission is inhibited.
Format error
00B0H Requested processing code is not supported
00B1H Inhibited status is demanded by control request
00B2H Requested year is invalid at time setting
00B3H Requested month is incorrect at time setting
00B4H Request day is incorrect at time setting
00B5H Request hour is incorrect at time setting
00B6H Request minute is incorrect at time setting
00B7H Request second is incorrect at time setting
00B8H Incorrect node address (other than 0 to 63) is set in response to
parameter setting request and explicit message request.
Component data error
00C0H Incorrect data is in the data constituting parameter setting request.
(See trace information for details.)
00C1H Slave device input/output data cannot be allocated to the input/output
data area.
Request number error
00C3H The number of devices specified in the I / O data request is invalid.
Содержание DeviceNet nv Series
Страница 1: ...Unified Controller nv Series type1 light DeviceNetTM Module DN611B Instruction Manual 6F8C1686 ...
Страница 30: ...Chapter 1 DN611B Introduction 6F8C1686 14 ...
Страница 92: ...Chapter 4 Settings 6F8C1686 76 3 Register the slave node Figure 4 16 Register the slave node Drag and Drop ...
Страница 149: ...13 3 133 B Appendix B Outside Dimension ...
Страница 150: ...Appendix B Outside Dimension 6F8C1686 134 Figure B 1 External dimension 135 mm 35mm 130 mm 111 5mm 105mm ...
Страница 151: ...13 5 135 C Appendix C Related products C 1 Network components 136 C 2 DeviceNet setting tool 138 ...
Страница 159: ...1686 2 2201 ...