4.
Assemble the rate control valve manifold,
gasket, and agitation-valve manifold with a
flange clamp and tighten by hand (
A).
5.
Assemble the rate control valve to the valve
mount with the 2 flanged-head bolts and 2
flanged locknuts (
A) that you removed
in step
of
Removing the Rate Control Manifold
, and torque the nut and bolt to
10 to 12 N∙m (90 to 110 in-lb).
6.
Assemble the outlet fitting onto the coupling
fitting at the bottom of the manifold for the rate
control valve (
7.
Secure the outlet fitting coupling fitting by
inserting a retainer into the socket of the outlet
fitting (
8.
If you loosened the mounting hardware for the
pressure filter head, tighten the nut and bolt to
10 to 12 N∙m (90 to 110 in-lb).
Installing the Agitation Manifold
Valve
1.
Align the flange of the agitation-valve manifold,
a gasket, and the flange of the agitation bypass
valve (
Note:
If needed, loosen the mounting hardware
for the master-boom valve as needed to provide
clearance.
g033604
Figure 127
1.
Flanged-head bolt (1/4 x
3/4 inch)
5.
Flange clamp
2.
Gasket
6.
Valve mount
3.
Manifold (agitation valve)
7.
3-pin connector (valve
actuator—agitation valve)
4.
Flanged locknut (1/4 inch)
2.
Assemble the agitation bypass valve, gasket,
and agitation-valve manifold with a flange clamp
and tighten by hand (
).
3.
Align a gasket between the flanges of the rate
control valve and the agitation-valve manifold
(
A).
g033605
Figure 128
1.
Flange (rate control valve)
5.
Coupling (manifold-valve)
2.
Flange (master-boom
valve)
6.
Socket (outlet fitting)
3.
Flange clamp
7.
Retainer
4.
Gasket
85