gear and drive the marked distance in a
straight line at full throttle.
•
For the
HDX-Auto model
,—shift the
machine into D (drive) and drive the marked
distance in a straight line at full throttle.
8.
Stop the machine at the marked-off distance
and select the checkmark on the InfoCenter.
Note:
Slow down and roll to a stop to align the
center of the front tires with the finish line, for
the most accurate measurement.
Note:
Calibration is now complete.
Calibrating the
Section-Bypass Valves
Before using the sprayer for the first time, whenever
you change the nozzles, or as needed, calibrate the
sprayer flow, speed, and set the section bypass.
Important:
Select an open flat area to perform
this procedure.
Note:
Calibrating the section bypass for
machines
without a throttle lock
requires 2 people.
Preparing the Machine
1.
Ensure that the sprayer tank is filled with water.
2.
Set the transmission as follows:
•
For HD-Series Models with a
manual
transmission
—shift the transmission to the
N
EUTRAL
position.
•
For the
HDX-Auto model
—shift the
transmission to P (park).
3.
Engage the parking brake and turn the engine
on.
4.
Set the 3 section switches to the O
N
position,
but leave the master-section switch in the O
FF
position.
5.
Set the pump switch to the O
N
position, and turn
on the agitation.
6.
Set the engine speed as follows:
•
For machines
without
the optional throttle
lock—have 1 person press down on the
accelerator pedal until the engine reaches
maximum engine speed.
Note:
Have the other person adjust the
section-bypass valves.
•
For machines
with
the optional throttle lock,
press down on the accelerator pedal until
the engine reaches maximum engine speed
and set the throttle lock; refer to operation
instructions for your Workman hand throttle
kit.
7.
On the InfoCenter, navigate to the Calibration
menu and select Test Speed.
Note:
Selecting the Home Screen icon at any
time cancels calibration.
8.
Using the plus (+) and minus (–) symbols, enter
a test speed of 5.6 km/h (3.5 mph), then select
the Home icon.
Adjusting the Section Bypass
Valves
1.
Using the application rate switch, adjust the
application rate according to the table that
follows.
Nozzle Application Rate Table
Nozzle Color
SI (Metric)
English
Turf
Yellow
159 L/ha
17 gpa
0.39 gpk
Red
319 L/ha
34 gpa
0.78 gpk
Brown
394 L/ha
42 gpa
0.96 gpk
Gray
478 L/ha
51 gpa
1.17 gpk
White
637 L/ha
68 gpa
1.56 gpk
Blue
796 L/ha
85 gpa
1.95 gpk
Green
1,190 L/ha
127 gpa
2.91 gpk
2.
Turn off the left-section switch and adjust the
left section-bypass valve (
) until the
pressure reading is at the previously adjusted
level (typically 2.75 bar or 40 psi).
Note:
The numbered indicators on the bypass
valve are for reference only.
g028047
Figure 85
1.
Section-bypass adjustment
3.
Turn on the left-section switch and turn off the
right-section switch.
4.
Adjust the right section-bypass valve (
until the pressure reading is at the previously
adjusted level (typically 2.75 bar or 40 psi).
5.
Turn on the right-section switch and turn off the
center-section switch.
55