InfoCenter Advisories
Operator advisories automatically display on the
InfoCenter screen when a machine function requires
additional action. For example, if you attempt to
start the engine while pressing the traction pedal, an
advisory displays indicating that the traction pedal
must be in the N
EUTRAL
position.
For each advisory that occurs, the fault indicator
flashes, and an advisory code (number), an advisory
description, and an advisory qualifier appears on the
screen as shown in
.
Advisory descriptions and qualifiers appear as
InfoCenter icons. Refer to
InfoCenter Icons (page 42)
for a description of each icon.
Note:
An advisory qualifier explains the conditions
that triggered the advisory and provides instructions
on eliminating the advisory.
g202867
Figure 75
1.
Fault indicator
3.
Advisory description
2.
Advisory qualifier
4.
Advisory code
Note:
Advisories do not log into the fault log.
Note:
You can clear an advisory from the display
screen by pressing any of the InfoCenter keys.
Refer to the table that follows for the InfoCenter
advisories:
Advisories
Advisory Code
Description
200
Start prevented—pump switch active
201
Start prevented—not in N
EUTRAL
202
Start prevented—out of seat
203
Start prevented—throttle pedal is not home
204
Start prevented—starter engage timeout
205
Parking brake is engaged
206
Pump start prevented—boom active
Advisories (cont'd.)
Advisory Code
Description
207
Pump start prevented—engine speed high
208
Throttle/speed lock prevented—pump is not
active
209
Throttle lock prevented—parking brake is
not engaged
210
Speed lock prevented—operator not in seat
or parking brake is engaged
211
Throttle/speed lock prevented—clutch or
service brake is engaged
212
Tank low volume alert
213
Rinse pump O
N
220
Flow sensor calibration
221
Flow sensor calibration—fill water in tank
and enter volume filled
222
Flow sensor calibration—turn on the pump
223
Flow sensor calibration—turn on all the
booms
224
Flow sensor calibration—calibration
commenced
225
Flow sensor calibration—calibration
complete
226
Flow sensor calibration—exiting calibration
mode
231
Speed sensor calibration
232
Speed sensor calibration—fill the
fresh-water tank, press next
233
Speed sensor calibration—fill the sprayer
half full of water, press next
234
Speed sensor calibration—enter the
calibration distance, press next
235
Speed sensor calibration—mark and drive
the entered distance with sprayer sections
off
236
Speed sensor calibration—speed sensor
calibration in progress
237
Speed sensor calibration—speed sensor
calibration complete
238
Speed sensor calibration—turn off the
booms
241
Calibration out of bounds, using default
48