H-5
Compound Name
Acronym
Library
(see key)
HRL
(ppm)
HRL
(mg/m3)
Detection
Limit
(ppm)
Detection
Limit
(mg/m3) Wavelength Pathlength
Accuracy
(+/-% of
reading)
STYRENE STYRNE-H
SL
1000
4268
15
64.02
11.076
Short
15
STYRENE STYRNE-L
SL
200
854
0.6
2.56
11.076
Long
15
STYRENE STYRNE-L
SL
200
854
0.7
2.99
12.980
Long
15
SULFUR DIOXIDE
SO2
SL
30
79
1.2
3.15
8.780
Long
10
SULFUR HEXAFLUORIDE (c)
SF6
SL
4
24 0.01 0.06 10.708 Long
1(10).
4(20)*
SULFURYL FLUORIDE
SULFRYLF
XL 30 125 0.1 0.418 11.550 Long
10
TETRAHYDROFURAN THF
XL
500 1478
0.5
1.48
8.660
Long
10
TOLUENE TOLUEN-H
SL
1000
3776
18
67.97
13.836
Short
10
TOLUENE
TOLUEN-H
SL
1000
3776 4 15.10 9.404 Long 10
TOLUENE TOLUEN-L
SL
200
755
1
3.78
13.836
Long
15
1.1.2-TRICHLORETHANE 3CLETHAN
XL 30 164 0.25 1.37 13.580 Long
10
1.1.2.2-TETRACHLOROETHANE 4CLETHAN XL 20 138 0.25 1.72 12.452 Long
10
TRICHLOROETHYLENE TCE
SL
1000
5384
4
21.54
10.764
Short
10
TRICHLOROETHYLENE TCE
SL
1000
5384
4
21.54
11.876
Short
15
VINYL ACETATE
VINLACET
XL
10 35 0.04 0.14 8.348 Long
15
VINYL CHLORIDE
VINLCLOR
SL 20 51 0.6 1.545 10.724 Long
10
VINYL CHLORIDE
VINLCLOR
SL 20 51 1.6 4.10 9.788 Long
10
VINYLIDENE CHLORIDE
VINLIDCL XL 20
79 0.2 0.79 12.692 Long 10
XYLENE XYLENE-H
SL
2000
8702
30
130.53
13.132
Short
10
XYLENE XYLENE-H
SL
2000
8702
7
30.46
12.600
Long
15
XYLENE XYLENE-L
SL
200
870
1.3
5.66
13.132
Long
15
Note
: The SapphIRe-SL contains those compounds with and “SL” in the library column. The
SapphIRe-XL contains all compounds in this list.
Accuracy is defined as +/- the average value displayed from five times the detection limit to the
full scale reading (e.g.. Acetaldehyde from 4.0 to 400 ppm: accuracy is +/- 10% of reading.
Detection limit is the point at which the analyzer will consistently and repeatably detect the
presence of the subject gas.
(a)
Carbon dioxide (absolute) refers to the measurement of CO
2
where the SapphIRe analyzer
has been purged with CO
2
free air such as nitrogen. Since CO
2
is present in the air at levels
of approximately 350 ppm and since the zero gas filter cannot scrub the CO
2
, the only way to
generate a true level of CO
2
is to flush or zero the analyzer with CO
2
free air. The factory
calibration for CO
2
was zeroed with nitrogen. Likewise, when using the CO
2
(absolute)
calibration, the analyzer must be zeroed with CO
2
free air.
(b)
Carbon dioxide (differential) refers to a measurement of CO
2
when the SapphIRe analyzer is
zeroed in a level of normal ambient air (350 ppm of CO
2
). When this calibration is used, a
background level of CO
2
must be added at the zero area to the analyzer’s display value.
(c)
0 to 1 ppm (
10%); 1 to 4 ppm (
20%)
Содержание MIRAN 205B Series
Страница 4: ......
Страница 14: ......
Страница 40: ......
Страница 54: ......
Страница 96: ......
Страница 102: ......
Страница 108: ......
Страница 112: ......
Страница 118: ......
Страница 122: ...Chapter 13 Infrared Spectroscopy Tutorial 13 2 Figure 13 1 Electromagnetic Spectrum ...
Страница 142: ......
Страница 170: ......
Страница 196: ......
Страница 202: ......
Страница 210: ......