Elapsed time range
0 to 100 hours (resets to 0 after 100 hours)
Time keeping and data retention
> 10 years
Readout display
LCD 16 characters (4 mm height) x 2 lines
Serial interface
High Speed USB/RS-232 (RS-232 is reserved for
wireless applications), 19,200 baud
Computer requirements
IBM-PC compatible, 486 or higher, Windows
™
’95 or
higher, > 8 MB memory, > 10 MB hard disk drive, CD
Drive, VGA or higher resolution monitor
Real-time digital signal (1 sec-1)
Concentration, flow, temperature, relative humidity,
barometric pressure, time, date
Real-time analog signal
1
0 to 2 V and 4 to 20 mA, with selectable full scale
ranges between 0.1 and 400 mg/m
3
0 - 0.1, 0 - 0.4, 0 - 1.0, 0 - 4.0, 0 - 10, 0 - 40, 0 - 100, and
0 - 400, mg/m
3
Minimum load impedance for voltage output: 200 k
Maximum load impedance for current output: 300
(
when powered by AC power supply)
Alarm output
Load impedance > 100 k
Alarm ON = short to ground
Alarm OFF = open
Internal battery run time
1.2 L/min (heater and alarm off) > 100-hour run-time
1.2 L/min (heater and alarm constantly on > 24-hour
run-time
3.5 L/min (heater and alarm constantly on > 12-hour
run-time
Internal battery charge time
4
95% charge capacity 7.3 hours (@100-250 VAC 50/60
Hz)
100% charge capacity 14 hours (@100-250 VAC 50/60
Hz)
AC source
100-240 VAC 50-60 Hz
12/24 VDC for solar or auxiliary battery options
Fuses
1.5 amp, slow blow fuse, 5 x 20 mm
Operating environment
-10
to
50
°
C
(14
to
122
°
F), 10 to 95% RH, non-
condensing
Storage environment:
-20
to 70
°
C (-4 to 158
°
F
)
Dimensions)
21 in (533 mm) H x 17 in (431 mm) W x 17 in (215 mm D
Weight
28.5 lbs. (12.9 kg)
Optional Cyclones
GK 2.05 (Red) primarily for PM
4
thru PM
10
SCC 1.062 (Blue) primarily for PM
1
thru PM
4
Содержание MIE ADR-1500
Страница 1: ...MIE ADR 1500 Instruction Manual Particulate Monitor Part Number 108836 00 15Nov2017 ...
Страница 4: ......
Страница 14: ...Figures x MIE ADR 1500 Instruction Manual Thermo Fisher Scientific ...
Страница 16: ...Tables xii MIE ADR 1500 Instruction Manual Thermo Fisher Scientific ...
Страница 26: ......
Страница 105: ...Maintenance and Service Thermo Fisher Scientific MIE ADR 1500 Instruction Manual 5 17 Figure 5 7 Wiring Diagram 2 ...
Страница 132: ......
Страница 140: ......