LLZ 421
Alignment Procedure LLZ−1F (LPD)
Operation and Maintenance
ILS 420
7−16
Ed. 07.08
SOAC
7.4.5
Check Alarm Limits and Alarm Delays
NOTE:
If upper limit is equal to lower limit, executive monitoring is not available.
7.4.5.1
Executive Alarm Limits
a) Open dialog ’Monitor 1 − Executive Alarm Limits’ and open dialog ’Monitor 2 − Executive Alarm
Limits’ (for MCS: dialogs ’Monitor 1/2 − Limits: Current Executive Data’).
b) Check that RF level alarm limits for all monitors are set to: 71 % (lower limit) and 110 % (upper limit).
c) Check that SDM alarm limits for all monitors are set to: 38 % (lower limit) and 42 % (upper limit).
d) Check that POS DDM alarm limits for all monitors are set to:
–0.9 % (lower limit) and +0.9 % (upper limit)
NOTE:
Used for CAT III only, CAT I and CAT II require other values, see section 7.8.
e) Check that CRS WIDTH DDM alarm limits for all monitors are set to:
–2.6 % (lower limit) and +2.6 % (upper limit) of actual measured value;
example for 15.5 %: 18.1 % (upper limit) and 12.9 % (lower limit)
f) Check that Ident AM alarm limits for all monitors are set to:
−2 % (lower limit) and +2 % (upper limit) of the actual measured value.
g) Check that Alarm delay time is set to: CAT I: 10 s; CAT II: 5 s; CAT III: 2 s (prefer. 1 s); NF: 20 s.
7.4.5.2
Far Field Alarm Limits
a) Open dialog ’Monitor 1 − Far Field Alarm Limits’ and dialog ’Monitor 2 − Far Field Alarm Limits’
(for MCS: dialogs ’Monitor 1/2 − Limits: Current Far Field Data’).
b) Check that RF level alarm limits for all monitors are set to: 71 % (lower limit) and 129 % (upper limit)
c) Check that SDM alarm limits for all monitors are set to: 38 % (lower limit) and 42 % (upper limit).
d) Check that POS DDM alarm limits for all monitors are set to:
–0.9 % (lower limit) and +0.9 % (upper limit)
NOTE:
Used for CAT III only, CAT I and CAT II require other values, see section 7.8. The alarm limits
are only available if an integrated FFM is installed.
7.4.5.3
Standby Alarm Limits
a) Open dialog ’Monitor 1 − Standby Alarm Limits’ and dialog ’Monitor 2 − Standby Alarm Limits’
(for MCS: dialogs ’Monitor 1/2 − Limits: Current Standby Data’).
b) Check that RF level alarm limits for all monitors are set to: 71 % (lower limit) and 110 % (upper limit)
c) Check that SDM alarm limits for all monitors are set to: 38 % (lower limit) and 42 % (upper limit).
d) Check that POS DDM alarm limits for all monitors are set to:
–0.9 % (lower limit) and +0.9 % (upper limit)
NOTE:
Used for CAT III only, CAT I and CAT II require other values, see section 7.8.
e) Check that CRS WIDTH DDM alarm limits for all monitors are set to:
–2.6 % (lower limit) and +2.6 % (upper limit) of actual measured value;
example for 15.5 %: 18.1 % (upper limit) and 12.9 % (lower limit)
REMARK:
Check pre−alarm limits. If need be adjust to 80 % of alarm limit value (recommended).
Содержание 421
Страница 2: ......
Страница 26: ...LLZ 421 General Operation and Maintenance ILS 420 1 6 Ed 01 04 SOAC ...
Страница 54: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 26 Ed 01 04 SOAC Ed 01 10 ...
Страница 56: ......
Страница 58: ......
Страница 66: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 38 Ed 01 10 SOAC ...
Страница 90: ...LLZ 421 Operation Operation and Maintenance ILS 420 3 24 Ed 01 10 SOAC ...
Страница 98: ...LLZ 421 Alignment Procedure LLZ 1F Dip Refl Operation and Maintenance ILS 420 4 8 Ed 01 10 SOAC ...
Страница 108: ...LLZ 421 Alignment Procedure LLZ 1F Dip Refl Operation and Maintenance ILS 420 4 18 Ed 01 10 SOAC ...
Страница 122: ...LLZ 421 Alignment Procedure LLZ 2F Dip Refl Operation and Maintenance ILS 420 5 8 Ed 07 08 SOAC ...
Страница 148: ...LLZ GP Maintenance Operation and Maintenance ILS 420 TEST DATA SHEET 6 8 Ed 01 10 SOAC ...
Страница 156: ...LLZ 421 Maintenance Operation and Maintenance ILS 420 6 14 Ed 01 10 SOAC ...
Страница 216: ...LLZ 421 Alignment Procedure LLZ 1F LPD Operation and Maintenance ILS 420 7 8 Ed 07 08 SOAC ...
Страница 238: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 8 Ed 07 08 SOAC ...
Страница 256: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 26 Ed 07 08 SOAC ...