TEST DATA SHEET
LLZ/GP
Operation and Maintenance
Maintenance
ILS 420
6−9
Ed. 01.10
SOAC
Test Data Sheet: Shutdown Path testing (with ECU −0001/−0002)
Test Item
Jumper set
Purpose
Action
Expected Result
Passed
Failed
Prerequisite:
Equipment in ’Normal’ con-
dition, both TX on, TX1 main
ECU
−0001/−0002
On LCP: Switch
key lock switch to
’MAINTENANCE’.
−
’Monitor Bypass’ set
−
Status ’Alarm’
(defeats the 20 s min. off time control)
TX1
J8:1−2, 9−10
Park position
Modulation shutdown path
(LGA1)
* GP active only
J8: 3−4
J8: 5−6
forces Syn 1
carrier gener.
remain ena-
bled:
Shutdown 1A
path will fail
Set ’TX1 off’.
check TP1, TP2
at MODPA1
2F equipment:
check TP1, TP2
also at MODPA2
−
Shutdown 1B should act
− ECU
shows
’Switch Fail’
− Alert warning ’ECU fault’
− SYN1: LED ’VCO off’ off
− CSB, SBO not present
(CRS)
−
CSB, SBO not present
(CLR); GP: CLR, CSB2*
TX2
J10:1−2,9−10 Park position
Modulation shutdown path
(LGA2)
* GP active only
J10: 3−4
J10: 5−6
forces Syn 2
carrier gener.
remain ena-
bled:
Shutdown 2A
path will fail
Set ’TX2off’.
check TP1, TP2
at MODPA1
2F equipment:
check TP1, TP2
also at MODPA2
−
Shutdown 2B should act
− ECU
shows
’Switch Fail’
− Alert warning ’ECU fault’
− SYN2: LED ’VCO off’ off
− CSB, SBO not present
(CRS)
−
CSB, SBO not present
(CLR); GP: CLR, CSB2*
ECU
J8,J10
Set to park posit.
Set TX1 on and "TX2 on"
TX1 is main
Reset ECU .
Clears the ECU fault:
−
’Switch fail’ is off
−
ECU Fault maint. warning
is removed (time < 30 s).
TX1
J9:1−2,9−10
Park position
Syn. carrier shutdown path
(SYN1)
* GP active only
J9: 3−4
J9: 5−6
forces modu-
lation gener.
path (LGA1)
remain ena-
bled:
Shutdown 1B
path will fail
Set ’TX1 off’.
check TP1, TP2
at MODPA1
2F equipment:
check TP1, TP2
also at MODPA2
−
Shutdown 1A should act
− ECU
shows
’Switch Fail’
− Alert warning ’ECU fault’
− SYN1: LED ’VCO off’ on
− CSB, SBO not present
(CRS)
−
CSB, SBO not present
(CLR); GP: CLR, CSB2*
TX2
J11:1−2,9−10 Park position
Syn. carrier shutdown path
(SYN2)
* GP active only
J11: 3−4
J11: 5−6
forces modu-
lation gener.
path (LGA2)
remain ena-
bled:
Shutdown 2B
path will fail
Set ’TX2 off’.
check TP1, TP2
at MODPA1
2F equipment:
check TP1, TP2
also at MODPA2
−
Shutdown 2A should act
− ECU
shows
’Switch Fail’
− Alert warning ’ECU fault’
− SYN2: LED ’VCO off’ on
− CSB, SBO not present
(CRS)
−
CSB, SBO not present
(CLR); GP: CLR, CSB2*
ECU
J9,J11
Set to park posit.
Set TX1 on and "TX2 on"
TX1 is main.
Reset ECU .
Clears the ECU fault:
−
’Switch fail’ is off
−
ECU Fault maint. warning
is removed (time < 30 s).
Set equipment to ’Normal’
condition, both TX ON.
Set key switch to
required mode.
Status ’Normal’, equipment is
in service again
Date:
Sign:
Содержание 421
Страница 2: ......
Страница 26: ...LLZ 421 General Operation and Maintenance ILS 420 1 6 Ed 01 04 SOAC ...
Страница 54: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 26 Ed 01 04 SOAC Ed 01 10 ...
Страница 56: ......
Страница 58: ......
Страница 66: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 38 Ed 01 10 SOAC ...
Страница 90: ...LLZ 421 Operation Operation and Maintenance ILS 420 3 24 Ed 01 10 SOAC ...
Страница 98: ...LLZ 421 Alignment Procedure LLZ 1F Dip Refl Operation and Maintenance ILS 420 4 8 Ed 01 10 SOAC ...
Страница 108: ...LLZ 421 Alignment Procedure LLZ 1F Dip Refl Operation and Maintenance ILS 420 4 18 Ed 01 10 SOAC ...
Страница 122: ...LLZ 421 Alignment Procedure LLZ 2F Dip Refl Operation and Maintenance ILS 420 5 8 Ed 07 08 SOAC ...
Страница 148: ...LLZ GP Maintenance Operation and Maintenance ILS 420 TEST DATA SHEET 6 8 Ed 01 10 SOAC ...
Страница 156: ...LLZ 421 Maintenance Operation and Maintenance ILS 420 6 14 Ed 01 10 SOAC ...
Страница 216: ...LLZ 421 Alignment Procedure LLZ 1F LPD Operation and Maintenance ILS 420 7 8 Ed 07 08 SOAC ...
Страница 238: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 8 Ed 07 08 SOAC ...
Страница 256: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 26 Ed 07 08 SOAC ...