LLZ 421
Alignment Procedure LLZ−1F (LPD)
Operation and Maintenance
ILS 420
7−10
Ed. 07.08
SOAC
7.3.4
Set Course SBO Amplitude (Course Width)
a) Switch both TX on and set TX1 on aerial.
b) Open dialog ’Transmitter1−Waveform Data#1’, open dialog ’Transmitter2−Waveform Data#1’.
c) Set parameter ’CRS CSB RF−Level’ of both TX to 15 W.
d) Set parameter ’CRS SBO Amplitude’ of both TX to 40 %.
e) Measure DDM with the portable DDM instrument at the width points of the threshold at a distance
of 107 m to the left or right (test point B or C, Fig. 7−6). Then set CRS SBO Amplitude so that DDM
is −15.5 % on left (150 Hz predominant), as seen from DDM measurement point or +15.5 % on
right (90 Hz predominant), as seen from DDM measurement point.
NOTE:
Sign + or − depends on measurement equipment used.
f) Set TX2 on aerial.
g) Set parameter ’CRS SBO Amplitude’ of TX2 for DDM 15.5 % at the width points, as well.
h) Note down amplitude values.
7.3.5
Measure Course Position at Threshold
Measure DDM with the portable DDM instrument at the threshold along the nominal course line at
at least 3 different points at a distance of approx. 10 m, and form the mean value. The mean value
should not deviate from the nominal course line by more than ±2m. If not repeat the null setting for
the course antenna. To perform this procedure refer to the appropriate Part 3 of the LLZ−manuals:
Antenna System Description for LPD 1F Antenna System, Sect. 9.5.4.
7.3.6
Performing Ground Check on Measurement Circle
Perform a ground check on the measurement circle (see Fig. 7−7) for each transmitter. Measure the
DDM and SDM on each ground check point (−35°, −30°,
…
, 0°,
…
, +30°, +35°) and draw a diagram
with these values. As example, a typical diagram resulting from measurement with a 14 element LPD
antenna is shown in Fig. 7−1.
NOTE:
The DDM should rise in linear fashion from the course line until it exceeds 18 %, then remain
greater than 18 % up to ±10° and greater than 15.5 % up to an azimuth angle of ±35°.
50 %
40 %
30 %
20 %
10 %
0%
−10 %
−20 %
−30 %
−40 %
−50 %
−60°
−40°
−20°
20°
40°
60°
Localizer (antenna 14 elements)
DDM
SDM
40 %
38 %
37 %
35 %
33 %
NOTE: Typical DDM and SDM values. Result of measurement depends on runway length and threshold distance
150 Hz predominant
90 Hz predominant
DDM
SDM
Runway
0°
linear range (±15.5 %)
−35°
35°
Fig. 7−1
Example diagram for ground check on measurement circle (LPD, 14 element)
Содержание 421
Страница 2: ......
Страница 26: ...LLZ 421 General Operation and Maintenance ILS 420 1 6 Ed 01 04 SOAC ...
Страница 54: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 26 Ed 01 04 SOAC Ed 01 10 ...
Страница 56: ......
Страница 58: ......
Страница 66: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 38 Ed 01 10 SOAC ...
Страница 90: ...LLZ 421 Operation Operation and Maintenance ILS 420 3 24 Ed 01 10 SOAC ...
Страница 98: ...LLZ 421 Alignment Procedure LLZ 1F Dip Refl Operation and Maintenance ILS 420 4 8 Ed 01 10 SOAC ...
Страница 108: ...LLZ 421 Alignment Procedure LLZ 1F Dip Refl Operation and Maintenance ILS 420 4 18 Ed 01 10 SOAC ...
Страница 122: ...LLZ 421 Alignment Procedure LLZ 2F Dip Refl Operation and Maintenance ILS 420 5 8 Ed 07 08 SOAC ...
Страница 148: ...LLZ GP Maintenance Operation and Maintenance ILS 420 TEST DATA SHEET 6 8 Ed 01 10 SOAC ...
Страница 156: ...LLZ 421 Maintenance Operation and Maintenance ILS 420 6 14 Ed 01 10 SOAC ...
Страница 216: ...LLZ 421 Alignment Procedure LLZ 1F LPD Operation and Maintenance ILS 420 7 8 Ed 07 08 SOAC ...
Страница 238: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 8 Ed 07 08 SOAC ...
Страница 256: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 26 Ed 07 08 SOAC ...