#PORT1_VCT_LEN=[0]
length of the line for cable tester for port
number 1, the same for other ports.
#SNMP_STATE=[0]
SNMP (0 – disabled, 1 — enabled)
#SNMP_SERVER=[0.0.0.0]
IP address of the SNMP Traps server
#SNMP_VERS=[0]
SNMP protocol version (0 – SNMP v1,
3– SNMP v3)
#SNMP_COMMUNITY1=[public]
reading community
#SNMP_COMMUNITY2=[private]
writing community
#SNMPV3_USER1_LEVEL=[0]
Security level (0 — NoAuth,NoPriv, 1 –
Auth,NoPriv, 2 – Auth,Priv)
#SNMPV3_USER1_USER_NAME=[]
User name for SNMP v3
#SNMPV3_USER1_AUTH_PASS=[]
Auth Password for SNMP v3
#SNMPV3_USER1_PRIV_PASS=[]
Priv Password for SNMP v3
#
SNMP3_ENGINE_ID
=[]
Engine ID for SNMP v3
#IGMP_STATE=[0]
IGMP (0 – disabled, 1 – enabled)
#IGMP_QUERY_MODE=[1]
IGMP General Query sending (0 –
disabled, 1 – enabled)
#IGMP_PORT_1_STATE=[1]
inclusion of port 1 in IGMP protocol, the
same for other ports.
#IGMP_QUERY_INTERVAL=[60]
IGMP Query Interval
#IGMP_QUERY_RESP_INTERVAL=[10]
IGMP Query response Interval
#IGMP_GROUP_MEMB_TIME=[250]
Group Membership Time
#IGMP_OTHER_QUERIER_INTERVAL=[25
5]
Other Querier Interval
#TELNET_STATE=[1]
Telnet state (0 – disabled, 1 — enabled)
#TFTP_MODE=[0]
TFTP mode (0 – disabled, 1 — enabled)
#TFTP_PORT=[69]
UDP port on TFTP
#PLC_EM_MODEL=[0]
Energy meter model
#PLC_EM_BAUDRATE=[5]
Speed of port RS485 (0 – 300, 1 – 600, 2
– 1200, 3 – 2400, 4 – 4800, 5 – 9600, 6 –
19200)
#PLC_EM_PARITY=[0]
RS485 parity (0 – Disable, 1 – Even, 2 –
Odd)
#PLC_EM_DATABITS=[8]
Number of data bits
#PLC_EM_STOPBITS=[1]
Number of stop bits