5.3.22 Set up Camera Comfort Start
Special Functions → Comfort Start
Comfort Start
– A safe start of the camera. The most problematic moment in
camera operations is its start at low temperature. To ensure comfortable conditions
for starting a camera in the cold season it is recommended to power on the heater of
the thermal housing and only then turn on the camcorder. Checked box enables 1 or 2
hours delay between powering on the switch and turning on PoE for the camera.
Attention!
This function is available only for outdoor PSW switches
Attention!
This function requires TFortis TH-02 or TH-03 thermal housings
Soft start time
– select the preheating duration. If the air temperature does not
fall below minus 30°C, it is recommended to set the preheating to 1 hour, for lower
temperatures, it is recommended to set it to 2 hours.
Manual start
– forced camera start without waiting for the preheating cycle to
finish.
Figure 5.3.22.1 Camera Comfort Start settings