HYDRAULIC PRESSURE GAUGE
The hydraulic pressure gauge registers the hydraulic
pressure in the main brush circuit. Normal down
pressure ranges with the brush up and running are
300 to 500 psi (2070 to 3450 kPa) and from 1800 to
2200 psi (12,410 to 15,170 kPa) with the brush down
and running. It is normal for the gauge needle to
move around. It moves around due to uneven or
high spots in the floor.
Prolonged pressures above 2250 psi (15,510 kPa)
will cause the wire brush to stall and will damage the
brush and hydraulic system.
STABILIZER LEG
The stabilizer leg projects forward to act as an
anti---tipping device when the machine is being high
dumped. Check the stabilizer leg to be sure it is
projecting forward when the machine is being high
dumped and is fully retracted when the hopper is in
the “operating” position.
A
B
01440
RETRACTED STABILIZER LEG
A. Machine Frame
B. Stabilizer Leg
FUSES AND CIRCUIT BREAKERS
Fuses are a one---time circuit protection device
designed to stop the flow of current in the event of a
circuit overload. Never substitute higher value fuses
than those specified in this manual.
Circuit breakers are reusable circuit protection
devices designed to stop the flow of current in the
event of a circuit overload. Once tripped, circuit
breakers must cool before they automatically reset.
If the overload which caused the circuit breaker to
trip is still present in the circuit, the circuit breaker
will continue to stop current flow until the overload is
corrected. The chart below shows the various fuses
and circuit breakers, the electrical components they
protect, and their locations in the machine.
PROTECTIVE
CIRCUIT
DEVICE
RATING
PROTECTED
LOCATION
FU--- 1
50 A
Diesel Glow Plug
Diesel Control Unit
CB--- 1
25 A
Dust Shaker Motors
Electric Breaker Box
CB--- 2
15 A
Operating Lamps
Electric Breaker Box
CB--- 3
15 A
Gauges
Electric Breaker Box
CB--- 4
15 A
Actuator
Electric Breaker Box
CB--- 5
15 A
Turn Signal Lamps
Electric Breaker Box
CB--- 6
15 A
Heater, Defroster, Fan
Electric Breaker Box
CB--- 7
15 A
Back--- up Alarm
Electric Breaker Box
Содержание 92 GR
Страница 1: ...Operator Manual...
Страница 10: ...SECTION 1 SPECIFICATIONS CONTENTS Page Machine Specifications 1 1 Machine Dimensions 1 3...
Страница 14: ...92GR MM188 6 87 1 4...
Страница 33: ...92GR MM188 10 87 2 18...
Страница 44: ...3 65545 92GR MM188 11 87 04307 HYDRAULIC SCHEMATIC...
Страница 56: ...3 65557 92GR MM188 11 87 04309 ELECTRICAL SCHEMATIC...
Страница 57: ...92GR MM188 11 87 3 65558 01502 ELECTRICAL SCHEMATIC ACCESSORIES...