Operating Information
2- 4
TLA7AXX Logic Analyzer Module Service Manual
CAUTION.
Static discharge can damage the TLACAL2 fixture and its associated
circuit boards. Make sure that you install the fixture in a static-free environment.
Always wear a grounded wrist strap while handling the TLACAL2 fixture and its
associated equipment. For more information on antistatic procedures, see
Preventing Electrostatic Discharge
on page 6--1.
Due to the short cable lengths, you must decide upon a location for the TLA-
CAL2 fixture that allows you to connect the test fixture to the logic analyzer
module under test (less than two feet). The fixture can be placed on top of a
benchtop mainframe or on a static free work surface adjacent to the logic
analyzer.
The following steps assume that you have all the required test equipment
necessary to run the performance verification procedures, certification proce-
dures, and adjustment procedures. See Table 4--1 on page 4--3 for a complete list
of test equipment.
1.
If you have not already done so, power down the mainframe and install the
logic analyzer module.
2.
Connect the RS-232 cable from the COM A connector of the logic analyzer
mainframe to the RS-232 connector on the performance verification fixture.
NOTE
. When using GPIB, make sure that you select unique GPIB addresses on
the individual instruments to avoid conflicts.
3.
Connect the GPIB cable from the digital multimeter to the oscilloscope.
4.
Connect the iView cable from the USB connector on the logic analyzer
mainframe to the GPIB connector on the DMM.
NOTE
. Steps 5 and 6 assume that you will be connecting the TLACAL2 fixture to
a 136-channel logic analyzer module. You only need to connect one MIC board
and one ribbon cable per 34 channels on the logic analyzer module. If your logic
analyzer module has less than 136 channels, you can reduce clutter by only
connecting the cables that you need for your instrument configuration.
5.
Connect one end of the ribbon cables to the MIC 0/PIC, MIC 1, MIC 2 and
MIC 3 connectors on the performance verification fixture.
Содержание TLA7AA1
Страница 5: ......
Страница 17: ...Service Safety Summary xii TLA7AXX Logic Analyzer Module Service Manual...
Страница 23: ...Preface xviii TLA7AXX Logic Analyzer Module Service Manual...
Страница 27: ...Introduction xxii TLA7AXX Logic Analyzer Module Service Manual...
Страница 63: ...Operating Information 2 20 TLA7AXX Logic Analyzer Module Service Manual...
Страница 105: ...Adjustment Procedures 5 4 TLA7AXX Logic Analyzer Module Service Manual Figure 5 1 TLACAL2 test fixture connections...
Страница 157: ...Troubleshooting 6 38 TLA7AXX Logic Analyzer Module Service Manual...
Страница 163: ...Electrical Parts List 8 2 TLA7AXX Logic Analyzer Module Service Manual...