TLA7AXX Logic Analyzer Module Service Manual
2- 1
Operating Information
This chapter provides a high-level overview of installation instructions and
operating information for the logic analyzer module. The operating information
is limited to the functions you need to perform the procedures found in this
document. You can find detailed operating instructions in the
Tektronix Logic
Analyzer Family User Manual
and in the online help.
Installation
The
Tektronix Logic Analyzer User Manual
provides detailed installation
instructions for the logic analyzer module and the mainframes. This section
contains a summary of those installation procedures. This section also describes
the installation procedures for the TLACAL2 Performance Verification and
Adjustment fixture; this fixture is required for the TLA7Axx series logic
analyzer module performance verification procedures, certification procedures,
and adjustment procedures.
Every plug-in module in the logic analyzer must have a unique logical address;
no two modules can have the same address. Two rotary switches on rear panel
select the logical address (see Figure 2--1 for the switch locations). When
servicing the logic analyzer module, you should have no need for changing the
address. However, in most cases the switches should be set to FF, the factory
default setting to enable dynamic auto configuration.
NOTE
. Do not set the logic analyzer module logical address to 00. Logical
address 00 is reserved for the controller.
Dynamic Autoconfiguration
With Dynamic Auto Configuration (recommended)
selected (hexadecimal FF or decimal 255), the logic analyzer automatically sets
the address to an unused value. For example, if there are modules set to
addresses 01 and 02 already in your system, the resource manager will automati-
cally assign the logic analyzer module an address other than 01 or 02.
Static Logical Address
Static logical address selections set the address to a fixed
value. A static logical address ensures that the logic analyzer module address
remains fixed for compatibility with modules that require a specific address
value. Remember that each module within the logic analyzer must have a unique
address to avoid communication problems.
Logical Address
Содержание TLA7AA1
Страница 5: ......
Страница 17: ...Service Safety Summary xii TLA7AXX Logic Analyzer Module Service Manual...
Страница 23: ...Preface xviii TLA7AXX Logic Analyzer Module Service Manual...
Страница 27: ...Introduction xxii TLA7AXX Logic Analyzer Module Service Manual...
Страница 63: ...Operating Information 2 20 TLA7AXX Logic Analyzer Module Service Manual...
Страница 105: ...Adjustment Procedures 5 4 TLA7AXX Logic Analyzer Module Service Manual Figure 5 1 TLACAL2 test fixture connections...
Страница 157: ...Troubleshooting 6 38 TLA7AXX Logic Analyzer Module Service Manual...
Страница 163: ...Electrical Parts List 8 2 TLA7AXX Logic Analyzer Module Service Manual...