Command groups
Table 2-40: Trigger commands (cont.)
Command
Description
TRIGger:{A|B}:BUS:B<x>:AUDio:DATa:
HITDMVALue
Sets or queries the binary data string for the high data word to be used when
triggering on an TDM audio bus signal.
TRIGger:{A|B}:BUS:B<x>:AUDio:DATa:
OFFSet
Sets the data offset value to be used when triggering on an audio bus signal.
TRIGger:{A|B}:BUS:B<x>:AUDio:DATa:
QUALi
Sets the quali
fi
er (<, >, =, <=, >=, not =, in range, out of range) to be used when
triggering on an audio bus signal.
TRIGger:{A|B}:BUS:B<x>:AUDio:DATa:
TDMVALue
Sets or queries the binary data string for the single or low data word to be used when
triggering on an TDM audio bus signal.
TRIGger:{A|B}:BUS:B<x>:AUDio:DATa:
VALue
Sets the lower word value to be used when triggering on an audio bus signal.
TRIGger:{A|B}:BUS:B<x>:AUDio:DATa:
WORD
Sets the alignment of the data (left, right or either) to be used to trigger on an
audio bus signal.
TRIGger:{A|B}:BUS:B<x>:CAN:CONDition
Sets the condition (start of frame, frame type, identi
fi
er, matching data, EOF, missing
ACK
fi
eld, bit-stuf
fi
ng error) to be used when triggering on a CAN bus signal.
TRIGger:{A|B}:BUS:B<x>:CAN:DATa:
DIRection
Sets the data direction (read, write or “nocare”) to be used to search on a CAN
bus signal.
TRIGger:{A|B}:BUS:B<x>:CAN:DATa:
OFFSet
Sets or queries the data offset value, in bytes, to use when triggering on the CAN
data
fi
eld.
TRIGger:{A|B}:BUS:B<x>:CAN:DATa:
QUALi
Sets the quali
fi
er (<, >, =, not =, <=, >=) to be used when triggering on a CAN bus
signal.
TRIGger:{A|B}:BUS:B<x>:CAN:DATa:SIZe
Sets the length of the data string, in bytes, to be used when triggering on a CAN
bus signal.
TRIGger:{A|B}:BUS:B<x>:CAN:DATa:VALue
Sets the binary data value to be used when triggering on a CAN bus signal.
TRIGger:{A|B}:BUS:B<x>:CAN:ERRType
Sets or queries the type of error condition for a CAN bus to triggering on.
TRIGger:{A|B}:BUS:B<x>:CAN:FD:BRSBit
Sets or queries the value of the bit rate switch bit (BRS bit) for a CAN bus to
triggering on.
TRIGger:{A|B}:BUS:B<x>:CAN:FD:ESIBit
Sets or queries the value of the error state indicator bit (ESI bit) for a CAN bus to
triggering on.
TRIGger:{A|B}:BUS:B<x>:CAN:FRAMEtype
Sets the frame type (data, remote, error or overload) to be used when triggering on
a CAN bus signal.
TRIGger:{A|B}:BUS:B<x>:CAN:IDenti
Sets the addressing mode (standard or extended format) to be used when triggering
on a CAN bus signal.
TRIGger:{A|B}:BUS:B<x>:CAN:IDenti
Sets the binary address value to be used when triggering on a CAN bus signal.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:
CONDition
Speci
fi
es a
fi
eld or condition within an Ethernet frame to trigger on.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:DATa:
HIVALue
When the Ethernet trigger condition is set to
DATa
, and the quali
fi
er is set to either
INrange
or
OUTrange
, this command speci
fi
es the upper data value of the range.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:DATa:
OFFSet
When the Ethernet trigger condition is set to
DATa
, this command speci
fi
es where in
the data
fi
eld to look for the data trigger value.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:DATa:
QUALi
Sets or queries the quali
fi
er to be used when triggering on an Ethernet bus signal.
MSO54, MSO56, MSO58, MSO58LP Programmer
2-77
Содержание MSO54
Страница 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Страница 2: ......
Страница 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Страница 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Страница 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Страница 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Страница 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...
Страница 938: ...Appendix A Character Set A 2 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Страница 996: ...Appendix D Waveform Transfer WFMOutpre and CURVe Query Examples D 18 MSO54 MSO56 MSO58 MSO58LP Programmer ...