Commands listed in alphabetical order
MEASUrement:MEAS<x>:MEASRange:MIN
This command sets or queries the range minimum value for the measurement.
Measurements are speci
fi
ed by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:MEASRange:MIN <NR3>
MEASUrement:MEAS<x>:MEASRange:MIN?
Arguments
<NR3>
is the minimum measurement range limit value.
Examples
MEASUrement:MEAS1:MEASRange:MIN -1.0
sets the minimum measurement
range to -1.0 V.
MEASUrement:MEAS1:MEASRange:MIN?
might return
:MEASUREMENT:MEAS1:MEASRANGE:MIN 0.0E+0
indicating the
minimum range is 0.0 V.
MEASUrement:MEAS<x>:MEASRange:STATE
This command sets or queries the range state for the measurement. Measurements
are speci
fi
ed by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:MEASRange:STATE {OFF|ON|0|1}
MEASUrement:MEAS<x>:MEASRange:STATE?
Arguments
OFF
turns off the measurement range limits.
ON
turns on the measurement range limits.
0
turns off the measurement range limits.
1
turns on the measurement range limits.
Examples
MEASUrement:MEAS1:MEASRange:STATE 0
turns off the measurement range
limits.
MEASUrement:MEAS1:MEASRange:STATE?
might return
:MEASUREMENT:MEAS1:MEASRANGE:STATE 1
indicating the
measurement range limits are on.
2-464
MSO54, MSO56, MSO58, MSO58LP Programmer
Содержание MSO54
Страница 1: ...xx 5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual P077130502 077 1305 02 ...
Страница 2: ......
Страница 3: ...5 Series MSO MSO54 MSO56 MSO58 MSO58LP ZZZ Programmer Manual xx www tek com 077 1305 02 ...
Страница 8: ...Preface iv MSO54 MSO56 MSO58 MSO58LP Programmer ...
Страница 26: ...Command Syntax 2 10 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Страница 936: ...Status and Events 3 20 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Страница 937: ...Appendix A Character Set MSO54 MSO56 MSO58 MSO58LP Programmer A 1 ...
Страница 938: ...Appendix A Character Set A 2 MSO54 MSO56 MSO58 MSO58LP Programmer ...
Страница 996: ...Appendix D Waveform Transfer WFMOutpre and CURVe Query Examples D 18 MSO54 MSO56 MSO58 MSO58LP Programmer ...