3008
Solenoid Current Too Low
Solenoid current is below the low current limit.
Go to SYSTEM OVERVIEW for
details
3009
Missing Pressure Sensor
Pressure sensor is not detected. Pressure sensor is
required for Operation Mode.
3010
Missing Boom Interface Module
Communication to the Boom Interface Module has been
lost. Boom Interface Module is required for Operation
Mode.
3011
Missing IOM Pressure Sensor
Communication to the Input Output Module (IOM) Pressure
Sensor has been lost. IOM Pressure Sensor is required for
Operation Mode
3012
Missing Driver(s)
Communication to a driver or drivers has been lost. All
drivers are required for Operation Mode.
Go to SYSTEM OVERVIEW for
details
3015
Minimum Duty Cycle Reached
Desired pressure is not being maintained by the system.
The control duty cycle has fallen to the minimum threshold.
3016
Above Maximum Duty Cycle
Desired pressure is not being maintained by the system.
The control duty cycle has risen above the maximum
threshold.
3017
Above High Pressure
System pressure is above the high pressure alarm value.
The duty cycle has reached the maximum and pressure is
still too high.
3018
Outside Droplet Size
Droplet size is not being maintained by the system.
3019
Above High Pressure
System pressure is above the high pressure alarm value.
3020
Below Low Pressure
Nozzle pressure is below the recommended nozzle
pressure range.
3021
Above High Pressure
Nozzle pressure is above the recommended nozzle
pressure range.
3022
Boom Setup Error
Number of implement nozzles and flow regulator nozzles
are mismatched.
Go to Main Menu-> Machine Setup
for details.
3028
At Initialisation, the following errors
may have occurred:
•
3002 Missing Start Terminator
•
3003 Missing End Terminator
•
3009 Missing Pressure Sensor
•
3022 Boom Setup Error
At least one or more initialisation errors has occurred.
NOTE: This alert replaces the above pop-ups ONLY at
Initialisation.
Review alerts on the Home screen
and/or System Overview for details
on the error(s). Once all errors have
been addressed, restart the system.
When an 8-ouput driver is installed,
see Initialsation Boom Setup Error
with 8-output Drivers for more
details.
3029
Operation Error: All Solenoids
Open
An issue on the system has occurred preventing access to
the Operation screen. To avoid additional issues, all
Solenoids have been opened.