User Interface
User Interface settings allow the operator to set the preferred UT,
boom section beep, and Turn Compensation Visual.
1.
From the Main setup screen, select
User Interface
.
Figure 5-15:
User Interface
Use Preferred UT
Sets the universal terminal (UT) preference.
►
If more than one UT is available on the ISOBUS CAN,
−
Select
On
to use the current UT
−
Select
Off
to use a different UT on the ISOBUS
CAN
NOTE: If all UTs are set to “Off”, the system will arbitrarily select
which UT to use.
►
If only one UT is available, select
Off
NOTE: This should always be set to “Off” unless another UT is on the
CAN bus.
Boom Section Beep
Enables/disables beep when a boom section is turned on or off.
Standard Turn Compensation Unlock
When unlocked, makes standard turn compensation available on the
Operation screen. Standard Turn Compensation allows for turn
compensated application on this console. With standard turn
compensation, average pressure is calculated from the active sections
width then centered over the active sections. If Advanced Turn
Compensation is unlocked, Standard Turn Compensation Unlock is
not available.
Contact an authorized TeeJet Technologies local dealer for unlock
code availability.
See bulletin 98-01563 Standard Turn Compensation Unlock for unlock
instructions.
Advanced Turn Compensation Unlock
When unlocked and used with a compatible rate controller, makes
advanced turn compensation available on the Operation screen.
Advanced Turn Compensation allows for turn compensated
application on this console when used with a compatible rate
controller. With advanced turn compensation, average pressure is
calculated from the active width but is centered over all sections
(active or inactive). If Advanced Turn Compensation is unlocked,
Standard Turn Compensation Unlock is not available.
Contact an authorized TeeJet Technologies local dealer for unlock
code availability.
See bulletin 98-01564 Advanced Turn Compensation Unlock for
unlock instructions.
Individual Nozzle Shutoff Unlock
When unlocked and used with a compatible rate controller, makes
Individual Nozzle Shutoff available. Individual Nozzle Shutoff allows
for up to 100 individual sections (allowing one nozzle per section) on
this console when used with a compatible rate controller. Individual
Nozzle Shutoff is required for rate controllers configured with more
than 30 sections.
Contact an authorized TeeJet Technologies local dealer for unlock
code availability.
See bulletin 98-0155 Individual Nozzle Shutoff Unlock for unlock
instructions.
Variable Rate (VRA) Unlock
When unlocked and used with a compatible rate controller, makes
Variable Rate (VRA) available. Variable Rate (VRA) allows for more
than one rate across the boom at the same time on this console when
used with a compatible rate controller.
Contact an authorized TeeJet Technologies local dealer for unlock
code availability.
See bulletin 98-01566 Variable Rate (VRA) Unlock for unlock
instructions.