Turn Compensation Visual Unavailable
Although turn compensation is active, the visual on the Operation
screen is not shown. The Turn Compensation Visual can be
enabled/disabled from the User Interface settings. Verify the Turn
Compensation Visual is enabled.
Figure 7-16:
Turn Compensation Visual Unavailable
Turn Compensation Unavailable
Turn Compensation is not available on the Operation screen. Turn
Compensation is locked. Contact an authorized TeeJet Technologies
local dealer for unlock code availability. See bulletin 98-01563
Standard Turn Compensation Unlock or bulletin 98-01564 Advanced
Turn Compensation Unlock for unlock instructions.
Figure 7-17:
Turn Compensation Unavailable
ALERT OVERVIEW
Alert
Code
Error
Description
Action
1002
Screen Resolution Alert
Display graphics are best seen on 480x480 screen
resolution. Graphic representations may be affected below
the recommended screen resolution.
Press the Accept key
1003
Softkey Size Alert
Due to size conformities, softkeys will use basic graphics.
Press the Accept key
1004
End User Licence Agreement
ALWAYS READ AND FOLLOW THE CHEMICAL LABEL’S
DIRECITONS. Droplet size classification is in accordance
with ISO 25358 at the date of publication. Classifications
are subject to change. The chemical being sprayed, tank
mixes, temperature, humidity, wind speed, vehicle speed,
etc. can influence the actual drop size.
Press the Accept key
Occurs on console power-up.
Operator must press the Accept key
to use the system
3002
Missing Start Terminator
Start terminator is not detected. Terminator is required for
Operation Mode.
3003
Missing End Terminator
End terminator is not detected. Terminator is required for
Operation Mode.
3004
Missing Solenoid
One or more solenoids are not detected.
Detecting all solenoids or ignoring one specific alert is
required for Operation Mode.
Go to SYSTEM OVERVIEW for
details
3005
Voltage Too High
Driver voltage is above the high voltage limit.
Go to SYSTEM OVERVIEW for
details
3006
Voltage Too Low
Driver voltage is below the low voltage limit.
Go to SYSTEM OVERVIEW for
details
3007
Solenoid Current Too High
Solenoid current is above the high current limit.
Go to SYSTEM OVERVIEW for
details