DynaJet® IC7140
98-05347-EN-R1_A4LT-DynaJetIC7140-UM.docx
1
2
3
4
5
6
7
8
9
A
59
Alert
Code
Error
Description
Action
3030
Operation Error: All Solenoids
Closed
An issue on the system has occurred preventing access to
the Operation screen. To avoid additional issues, all
Solenoids have been closed.
Please stop application and address
the operation issue
3031
Solenoid Not Working Properly
Note: This alert is only available on
select configurations.
At least one or more solenoids are not opening or closing
completely.
Go to SYSTEM OVERVIEW for
details on the error(s).
3032
Turn Compensation Disengaged
Communication with the speed source has been lost.
Speed is required for turn compensation. Turn
compensation has been disengaged.
Verify speed source availability. Use
the Turn Compensation On key on
the Operation Screen to turn
compensation on.
3033
Missing Rate Controller: All
Solenoids Open
Communication with the Rate Controller has been lost. To
avoid additional issues, all Solenoids have been opened.
Verify Rate Controller is available
then restart the system.
3034
Missing Rate Controller: All
Solenoids Closed
Communication with the Rate Controller has been lost. To
avoid additional issues, all Solenoids have been closed.
Verify Rate Controller is available
then restart the system.
3100
Standard Turn Compensation
Unlock Successful!
The Standard Turn Compensation feature is now unlocked. Restart the system to begin using
Standard Turn Compensation.
3101
Standard Turn Compensation
Unlock Failed!
The Standard Turn Compensation feature remains locked.
Verify unlock code. Reenter unlock
code.
3102
Advanced Turn Compensation
Unlock Successful!
The Advanced Turn Compensation feature is now
unlocked.
Restart the system to begin using
Advanced Turn Compensation.
3103
Advanced Turn Compensation
Unlock Failed!
The Advanced Turn Compensation feature remains locked. Verify unlock code. Reenter unlock
code.
3104
Individual Nozzle Shutoff Unlock
Successful!
The Individual Nozzle Shutoff feature is now unlocked.
Restart the system to begin using
Individual Nozzle Shutoff.
3105
Individual Nozzle Shutoff Unlock
Failed!
The Individual Nozzle Shutoff feature remains locked.
Verify unlock code. Reenter unlock
code.
3106
Variable Rate (VRA) Unlock
Successful!
The Variable Rate (VRA) feature is now unlocked.
Restart the system to begin using
Variable Rate (VRA).
3107
Variable Rate (VRA) Unlock Failed! The Variable Rate (VRA) feature remains locked.
Verify unlock code. Reenter unlock
code.