DynaJet® IC7140
www.teejet.com
48
1
2
3
4
5
6
7
8
9
A
Figure 7-7:
Previous / Next Driver
Solenoid Information
The information box displays the selected solenoid number, location
and current through the coil. Solenoid location is notated with the
driver number (D) and output number (N).
Figure 7-8:
Solenoid Information
To access another solenoid on the selected driver:
1.
Press NEXT SOLENOID KEY.
Figure 7-9:
Next Solenoid
SYSTEM ERRORS
Errors with components of the system are displayed graphically on the
System Overview screens to help the operator locate any problems.
NOTE: Operation errors appear on the Operation screen. See the
Operation chapter for details.
Pop-up Alert Screens
If there is an active error, an alert screen will appear providing specific
information, associated error code and a softkey to go directly to the
System Overview screen.
See "Appendix C – TROUBLESHOOTING GUIDE" for details on
specific errors.
Figure 7-10:
System Alert Example
Use these softkeys to navigate from the pop-up screen:
System Overview – Press to go to the System Overview
screens for troubleshooting issues
Accept – Press to acknowledge a system alert and return
to the previous screen
System Overview – Press to go to the System Overview screens for
troubleshooting issues
Accept – Press to acknowledge a system alert and return to the
previous screen
NOTE: Ignored and/or accepted driver and solenoid errors will be
acknowledged on their associated information screens.
Current
Number
Location