4-8
Code
Name
Data setting range
C
ha
nge
w
hen
run
ning
D
a
ta
c
op
y
ing
Default
setting
Drive control
Refer to
Page
V/f
Vector
Control w/
PG
Torque
control
w/o
PG
70 (1070): Speed valid
(
DNZS
)
N
Y
Y
Y
4-88
71 (1071): Speed agreement
(
DSAG
)
N
Y
Y
N
72 (1072): Frequency (speed) arrival signal 3 (
FAR3
)
Y
Y
Y
N
76 (1076): PG error detected
(
PG-ERR
)
N
Y
Y
N
82 (1082): Positioning completion signal
(
PSET
)
N
N
Y
N
84 (1084): Maintenance timer
(
MNT
)
Y
Y
Y
Y
98 (1098): Light alarm
(
L-ALM
)
Y
Y
Y
Y
99 (1099): Alarm output (for any alarm)
(
ALM
)
Y
Y
Y
Y
101 (1101): Enable circuit failure detected
(
DECF
)
Y
Y
Y
Y
102 (1102): Enable input OFF
(
EN OFF
)
Y
Y
Y
Y
105 (1105): Braking transistor broken
(
DBAL
)
Y
Y
Y
Y
111 (1111): Customizable logic output signal 1 (
CLO1
)
Y
Y
Y
Y
112 (1112): Customizable logic output signal 2(
CLO2
)
Y
Y
Y
Y
113 (1113): Customizable logic output signal 3(
CLO3
)
Y
Y
Y
Y
114 (1114): Customizable logic output signal 4(
CLO4
)
Y
Y
Y
Y
115 (1115): Customizable logic output signal 5(
CLO5
)
Y
Y
Y
Y
Setting the value in parentheses ( ) shown above
assigns a negative logic output to a terminal.
E30 Frequency Arrival
(Hysteresis
width)
0.0 to 10.0 Hz
Y
Y
2.5
Y
Y
Y
N
4-93
E31 Frequency Detection 1 (Level) 0.0 to 500.0 Hz
Y
Y
60.0
Y
Y
Y
Y
4-94
E32
(Hysteresis width) 0.0 to 500.0 Hz
Y
Y
1.0
Y
Y
Y
Y
E34 Overload Early Warning/Current
Detection
(Level)
0.00 (Disable); Current value of 1% to 200% of the
inverter rated current
Y
Y1 Y2
*2
Y
Y
Y
Y
4-95
E35
(Timer) 0.01 to 600.00s
Y
Y
10.00
Y
Y
Y
Y
E36 Frequency Detection 2 (Level) 0.0 to 500.0 Hz
Y
Y
60.0
Y
Y
Y
Y
4-96
E37 Current Detection 2/
Low Current Detection (Level)
0.00 (Disable); Current value of 1% to 200% of the
inverter rated current
Y
Y1 Y2
*2
Y
Y
Y
Y
4-96
E38
(Timer) 0.01 to 600.00 s
Y
Y
10.00
Y
Y
Y
Y
4-96
E40 PID Display Coefficient A
-999 to 0.00 to 9990
Y
Y
100
Y
Y
Y
N
4-96
E41 PID Display Coefficient B
-999 to 0.00 to 9990
Y
Y
0.00
Y
Y
Y
N
E42 LED Display Filter
0.0 to 5.0 s
Y
Y
0.5
Y
Y
Y
Y
4-97
E43 LED Monitor
(Item selection) 0: Speed monitor (select by E48)
3: Output current
4: Output voltage
8: Calculated torque
9: Input power
10: PID command
12: PID feedback amount
14: PID output
15: Load factor
16: Motor output
17: Analog input
23: Torque current (%)
24: Magnetic flux command (%)
25: Input watt-hour
Y
Y
0
Y
Y
Y
Y
4-98
E44 Display when stopped
0: Specified value 1: Output value
Y
Y
0
Y
Y
Y
Y
4-99
E45 LCD Monitor (Item selection)
0: Running status, rotational direction and operation
guide
1: Bar charts for output frequency, current and
calculated torque
Y
Y
0
Y
Y
Y
Y
E46 Language selection
Type: TP-G1W-J1
0: Japanese
1: English
2: German
3: French
4: Spanish
5: Italian
Y
Y
1
Y
Y
Y
Y
4-100
E47 Contrast control
0 (Low) to 10 (High)
Y
Y
5
Y
Y
Y
Y
E48 LED Monitor(Speed
monitor
item)
0: Output frequency 1 (Before slip compensation)
1: Output frequency 2 (After slip compensation)
2: Reference frequency
3: Motor speed in r/min
4: Load shaft speed in r/min
5: Line speed in m/min
7: Display speed in %
Y
Y
0
Y
Y
Y
Y
4-100
*2 The motor rated current is automatically set. See Table B (P03/A17).
Item values in parentheses indicated value for negative logic.
Y: Applicable / N: Not Applicable.