4-6
E codes: Extension Terminal Functions
Code
Name
Data setting range
C
ha
nge
w
hen
run
ning
D
a
ta
c
op
y
ing
Default
setting
Drive control
Refer to
Page
V/f
Vector
Control w/
PG
Torque
control
w/o
PG
Selecting function code data assigns the corresponding
function to terminals [X1] to [X7] as listed below.
4-71
E01 Terminal [X1] Function
0 (1000): Select multi-frequency (0 to 1 steps)
(
SS1
)
N
Y
0
Y
Y
Y
N
E02 Terminal [X2] Function
1 (1001): Select multi-frequency (0 to 3 steps)
(
SS2
)
N
Y
1
Y
Y
Y
N
E03 Terminal [X3] Function
2 (1002): Select multi-frequency (0 to 7 steps)
(
SS4
)
N
Y
2
Y
Y
Y
N
E04 Terminal [X4] Function
3 (1003): Select multi-frequency (0 to 15 steps)
(
SS8
)
N
Y
3
Y
Y
Y
N
E05 Terminal [X5] Function
4 (1004): Select ACC/DEC time (2 steps)
(
RT1
)
N
Y
4
Y
Y
Y
N
E06 Terminal [X6] Function
5 (1005): Select ACC/DEC time (4 steps)
(
RT2
)
N
Y
5
Y
Y
Y
N
E07 Terminal [X7] Function
6 (1006): Enable 3-wire operation
(
HLD
)
N
Y
8
Y
Y
Y
Y
7 (1007): Coast to a stop
(
BX
)
Y
Y
Y
Y
8 (1008): Reset alarm
(
RST
)
Y
Y
Y
Y
9 (1009): Enable external alarm trip
(
THR
)
(9 = Active OFF, 1009 = Active ON)
Y
Y
Y
Y
10 (1010): Ready for jogging
(
JOG
)
Y
Y
Y
N
11 (1011): Select frequency command 2/1
(
Hz2/Hz1
)
Y
Y
Y
N
12 (1012): Select motor 2
(
M2
)
Y
Y
Y
Y
13:
Enable DC braking
(
DCBRK
)
Y
Y
Y
N
14 (1014): Select torque limiter level 2/1
(
TL2/TL1
)
Y
Y
Y
Y
15:
Switch to commercial power (50 Hz)
(
SW50
)
Y
N
N
N
16:
Switch to commercial power (60 Hz)
(
SW60
)
Y
N
N
N
17 (1017): UP (Increase output frequency)
(UP)
Y
Y
Y
N
18 (1018): DOWN (Decrease output frequency)
(DOWN)
Y
Y
Y
N
19 (1019): Enable data change with keypad
(WE-KP)
Y
Y
Y
Y
20 (1020): Cancel PID control
(Hz/PID)
Y
Y
Y
N
21 (1021): Switch normal/inverse operation
(
IVS
)
Y
Y
Y
N
22 (1022): Interlock
(
IL
)
Y
Y
Y
Y
23 (1023): Cancel torque control
(
Hz/TRQ
)
N
N
N
Y
24 (1024):Enable communications link via
RS-485 or fieldbus (option)
(
LE
)
Y
Y
Y
Y
25 (1025): Universal DI
(
U-DI
)
Y
Y
Y
Y
26 (1026): Enable auto search for idling motor
speed at starting
(
STM
)
Y
Y
N
Y
30 (1030): Force to stop
(
STOP
)
(30 = Active OFF, 1030 = Active ON)
Y
Y
Y
Y
32 (1032): Pre-excitation
(
EXITE
)
N
Y
Y
N
33 (1033): Reset PID integral and differential
components
(
PID-RST
)
Y
Y
Y
N
34 (1034): Hold PID integral component
(
PID-HLD
)
Y
Y
Y
N
35 (1035): Select local (keypad) operation
(
LOC
)
Y
Y
Y
Y
39:
Protect motor from dew condensation
(
DWP
)
Y
Y
Y
Y
40:
Enable integrated sequence to switch
to commercial power (50 Hz)
(
ISW50
)
Y
N
N
N
41:
Enable integrated sequence to switch
to commercial power (60 Hz)
(
ISW60
)
Y
N
N
N
47 (1047): Servo-lock command
(
LOCK
)
N
N
Y
N
48:
Pulse train input (available only on
terminal [X7] (E07))
(
PIN
)
Y
Y
Y
Y
49 (1049): Pulse train sign (available on terminals
except [X7] (E01 to E06))
(
SIGN
)
59 (1059): Enable battery operation
(BATRY)
Y
Y
Y
Y
Y
Y
Y
Y
70 (1070): Cancel constant peripheral speed
control
(
Hz/LSC
)
Y
Y
Y
N
71 (1071): Hold the constant peripheral speed
control frequency in the memory
(
LSC-HLD
)
Y
Y
Y
N
72 (1072): Count the run time of commercial
power-driven motor 1
(
CRUN-M1
)
Y
N
N
Y
73 (1073): Count the run time of commercial
power-driven motor 2
(
CRUN-M2
)
Y
N
N
Y
76 (1076): Select droop control
(
DROOP
)
Y
Y
Y
N
77 (1077): Cancel PG alarm
(
PG-CCL
)
N
N
Y
Y
80 (1080): Cancel customizable logic
(
CLC
)
Y
Y
Y
Y
81 (1081): Clear all customizable logic timers
(
CLTC
)
Y
Y
Y
Y
100: No function assigned
(
NONE
)
Y
Y
Y
Y
Setting the value in parentheses ( ) shown above assigns a
negative logic input to a terminal.
The shaded function codes are applicable to the quick setup.
Y: Applicable / N: Not Applicable.