![TEC BlowerDoor Standard Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/tec/blowerdoor-standard/blowerdoor-standard_manual_4022808075.webp)
Appendix A: Technical Data
BlowerDoor Standard
January 2022
75
Digital Pressure Gauge DG-1000 continued
Power:
Two lithium ion batteries (rechargeable and replaceable; size
18650, 2600 mAh, 3.7v, protected), charging via the supplied
USB-C-charger
Battery Life:
Over 15 hours of continuous use with default settings, 13 hours
of continuous use with default settings and WiFi or Bluetooth
active
Auto-Off Time
Adjustable from 10 minutes to never (= no auto off)
Dimensions:
(L x W x H) 177 x 107 x 36 mm
Weight:
approx. 445 g
Compatibility:
Compatible with all TEC devices
Stand-alone:
Cruise control for one-point measurement: Automatically
maintains a building pressure differential of 0, 25, 50, 75 Pa or
customer defined pressure differential.
Connections to PC/laptop:
WiFi, USB-C, and Ethernet connection
Connection to mobile device
Bluetooth
In connection with a laptop:
Automated test, semi-automated test (TECTITE Express)
Logging data of pressure differentials (TECLOG)
Recommended Calibration Interval:
2 years
A.3
Software TECTITE Express
Version
5.1
Indication for Belgium
Software tested according to the specifications of annex 1 of
STS-P 71-3.