60
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
PROBLEM
CAUSE
SOLUTION
The TRB
internal light
does not
flash.
- The wiring between
the TRB modules and
the main controller is
incorrect.
- Fix the wiring
- The ID numbers are
incorrect
- Set the proper ID numbers on
the TRB modules. Make sure
the modules have all different
ID# and that the numbers
follow numerical order.
- The end of line
jumpers are not
positioned correctly
- Set the end of line jumpers to
YES at both ends of the
communication line. The other
end of line jumpers must be set
to NO.
- The TRB is defec-
tive.
- Replace the TRB module.
Communication
alarm.
- The ID numbers are
incorrect
- Check all ID numbers. Make
sure the modules have all
different ID# and that the
numbers follow numerical
order. ID#1 is reserved for the
LCT module.
- There is a problem
with the TRB power
supply.
- The wiring between
the TRB modules and
the main controller is
incorrect.
- Fix the wiring
- Make sure all TRB modules
are powered properly by
activating manually each relay.
- A TRB module is
defective.
- Replace the TRB module.
13
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
4.3
Feed Scale
Menus
1 Date/Time Menu
1. Date/Time
1. Date/Time
Date: 200X/01/01
Time: 12:00:00
FeedWeigher for
Breeders V.X.X
1. Date/Time
1 Date/Time Menu
2. Day of week
2. Day of week
Current Day: Wed.
2a. Blend Menu
1. Blend #1
(...)
8. Blend #8
2a.1 Blend #1
Bin 1:
50%
Bin 1:
50%
Total:
100%
FeedWeigher for
Breeders V.X.X
2a. Blends
2a. Blend Menu
9. Substitution
Blends Substitution
1. Days House 1
2. Days House 2
House x Substitution
Su Mo Tu We Th Fr Sa
Blends Substitution
3. Blends Substit.
Substitute Blend
Blend 1 ->
1
Blend 2 ->
2
Blend 3 ->
3
2b. Feed Curve
1. Males
2. Females
2b.1 Feed Curve M
Use Curve ? No
1.Day 1 Feed: 20.3
1.Day 15 Feed: 25.3
FeedWeigher for
Breeders V.X.X
2b. Feed Curve