48
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
5.8.3 Scale Settings
The following section describes how to customize the scale for
your particular application. Normally, this setup needs to be done
only once.
Select "
9. Installation
" from the main menu using the up and down-
arrow keys. Press the right-arrow key.
Accessible from the installer mode only (s. 5.8.1).
Press the down-arrow key once to se-
lect the "
2.Scale Settings
" menu.
Press the right-arrow key then use the
adjustment buttons to set the following
parameters:
Actual Weight:
Shows current weight reading. This
value cannot be modified.
Max Batch:
-
For scales with valve
This is the maximum amount of feed
that can be contained in the scale
hopper (see figure in section 2.2). It
can be adjusted from 10 to 300kg
(22 to 661 lbs).
-
For scales without valve:
This is the maximum feed that can
be weighed in the receiving hopper (see figure in section 2.2).
It can be adjusted from 10 to 300kg (22 to 661 lbs).
Proxy Switch
:
Select "Yes" if the proximity switch sensor is used to prevent the
receiving hopper from overflowing. If it is enabled, the controller
automatically sets off an alarm when feed is detected by this sen-
sor; this means the receiving hopper is full. The bin auger is also
stopped when this type of alarm occurs.
9. Installation
2. Scale Settings
Actual Weight: 0.00
Max Batch: 20kg
Prox Switch ? Yes
Stability tol: 100
Empty tolerance:0
Valve Auto
Empty time 1:00
25
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
5.3.3.3 Consumption History
The consumption history menu gives the daily amount of feed taken
from each bin, for the past 21 days.
Select the "
3. Bin Information
" from
the main menu using the up and down-
arrow keys (or simply press the
corresponding short-cut key).
Select the desired bin using the up and
down-arrow keys. Press the right-ar-
row key.
Press the down-arrow key once to
select the "
2. History
" menu. Press
the right-arrow key.
Press the right-arrow key once again
to select the "
1. Consumption
" menu.
The daily feed consumption of the past
21 days is displayed. Press the down-
arrow key to scroll the display.
To clear this history, simultaneously
press and hold the + & - keys for a 3
second delay.
Feed Weigher for
Breeders VX.X
3. Bin Information
3.1.2 Bin #1 History
1. Consumption
Bin 1 Consumption
200X/01/01 12:00 1
Weight 176 kg
3.1. Bin 1 Info
2. History