7. TROUBLESHOOTING GUIDE
PROBLEM
CAUSE
SOLUTION
- The fuse of the
PSFS-1 is blown
The valve
does not open
when the
PSFS-1 is
connected.
- Turn the power off and
replace the fuse with a 2.5A
slow blow fuse.
Make sure not
to bend the fuse holder !
- There is a problem
with the power supply.
- Check for 12VAC at
the 12VAC terminals
of the PSFS-1.
- The wiring is incorrect
- The transformer is defective
- Check for 12 to 20VDC on
the MOTOR terminals of the
PSFS-1.
- Remove all wires from the
DIR terminal of the PSFS-1: if
the valve opens, then the 2
motor wires are inverted.
Interchange the 2 wires going
to the motor.
- The PSFS-1 is
defective
- Replace the PSFS-1 module.
The main
controller
does not turn
on.
- Fuse F1 is blown.
- Replace the fuse.
- The wiring is incorrect. - Turn off the power.
- Remove all wires from the
MODULE terminals of the
main controller.
- Wait 5 minutes.
- Apply power to the main
controller : If the controller
starts then there is a wiring
problem.
- Fix the wiring.
15
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
FeedWeigher for
Breeders V.X.X
4. House 1
4. House 1
2. Consumption
4.2 House1 Cons.
M (/100): 250g
Males(Tot) 10 kg
F (/100): 700g
Fem.(Tot) 35 kg
4. House 1
3. Feed Schedule
4.3 House1 Feed
Schedule
1. Feeding Days
4.3 House1 Feed
Schedule
2. Cycle #1
3. Cycle #2
4. House 1
1. Information
4.1 House 1 Info
Age
10
Feed today:
Yes
Current Cycle:
2
Total Weight
20
Delivered:
3
Bin Auger
2
Current Drop
7
Actual Weight
0.70
Scale Status
Dump
4.3.x House 1,Cyclex
Cycle:
On
Start Time:
12:00
Male (/100)
3kg
Fem. (/100)
3kg
Drop #1
Blend
1
% of Feed
10%
...
Drop #20
Blend
2
% of Feed
4.3 House1 Feed
Schedule
4. Manual mode
4.3.x House 1,Cyclex
Cycle:
On
Start Time:
12:00
Drop #1
Blend
1
Feed qty:
6kg
...
Drop #20
Blend
2
Feed qty
5kg
4.4 House1, Manual
Current Cycle
Pause:
No
Manual Mode
Status:
Off
Drop #1
Blend:
1
Feed qty: 0kg
Drop #2 (...)
4.3 Schedule
Frequency:
1/8
Days Left:
6
Next Day Skip: Tue.
or