6. Use the up- and down-arrow keys to select the proper type of transfer:
MEMORY CARD
CONTROLLER:
To transfer the memory card's content
into the controller, select the
"Mem.Card
Ctrl"
.
Once it is selected, simulta-
neously press the +and - buttons to
start the transfer.
CONTROLLER
MEMORY CARD:
To save the controller's configuration
into the memory card, select the
"Ctrl
Mem.Card "
menu. Once it is se-
lected, simultaneously press +and - but-
tons to start the transfer.
7. Once the transfer is over, simultaneously
press and hold the up- and down-arrow
keys for 5 seconds to exit the transfer
menu, then remove the memory card from
the connector as follows:
- Turn off power to the controller;
- Open the controller's cover;
- Remove the card from the connector;
- Close the cover then reapply power to
the controller.
8. Lock the card’s switch ( ) if required.
IMPORTANT:
REMOVE THE
MEMORY CARD
FROM THE
CONNECTOR WHEN
THE TRANSFER
IS OVER!
Mem.Card > Ctrl
+/- to start
Ctrl > Mem. Card
+/- to start
TRANSFER ERROR
The controller will not warn you if the transfer is incorrect.
Respect the following rules to make sure the transfer works properly:
•
Make sure the card switch is at the unlocked position before
transferring a configuration on the card.
•
Do not move or hold the card while a transfer is ongoing.
5
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
1. INTRODUCTION
1.1 Precautions, Care & Maintenance
WARNING: Read and save
these instructions!
Safety may be jeopardized if the equipment is used in a manner not specified by
the manufacturer. Carefully read and keep the following instructions for future
reference.
•
Although fuses at the input and outputs of the controller protect its
circuits in case of an overload or overvoltage, we recommend installing
an additional protection device on the controller's supply circuit.
•
The room temperature where the controller is located must always remain
between 32 °F and 104 °F (0 °C to 40 °C). For Indoor use only !
•
To avoid exposing the controller to harmful gases or excessive humidity,
it is preferable to install it in a corridor.
•
Do not spray water on the controller! In order to clean the control, wipe
it with a damp cloth.
Before servicing or cleaning unit, switch power off at
service panel and lock the switch disconnecting means to
prevent power from being switched accidentally. When the
service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
•
The controller should be opened and inspected once a year for mois-
ture. Proper care will extend the life of the control.
IMPORTANT:
Use Grounded Metallic Conduits Only!
The conduit that brings feed into the scale must absolutely be
made of metal and must be grounded in order to prevent static
electricity. A high static electrical charge may cause malfunc-
tion to the controller.