16
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
FeedWeigher for
Breeders V.X.X
6. Time Clocks
7. Alarm Log
8. Ack Alarm
6. Time Clocks
1. Time Clock#1
2. Time Clock#2
Run: Alw
On 1 6:00 Off 6:30
On 2 8:45 Off 9:30
On 3 9:45 Off 11:00
4. House 1
6. History
4.6 House 1 History
1. Males
2. Females
4.6.1 House 1 M Hist
1. Mortality
2. Cons. /100
3. Total Cons.
4. Cons. Correct.
4. House 1
7. Blend Curves
4.7 House 1 Blend
Curves
1. Males
2. Females
4.7.1 M Blend Curve
Use curve ?
Yes
1.Da 1 Blend 1
2.Da 25 Blend 2
4. House 1
5. Start Flock
4.5 House 1 Start
Start Age:
1
Males Entered: 20
Fem. Entered: 200
Start Flock ? No
FeedWeigher for
Breeders V.X.X
4. House 1
4. House 1
4. # of Birds
4.4 House 1 Birds
Males
Entered:
10
New Mortal.:
0
Mortality:
1
Tot.Mortal.:
2
Remaining:
8
Females
Entered:
150
New Mortal.:
0
Mortality:
5
Tot.Mortal.:
25
Remaining:
125
57
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
6.
MANUAL MODE
A manual mode allows the user to pause or abort a running feed
cycle or to start a cycle.
Select the desired house from the main menu using the arrow keys.
Press the right-arrow key.
Select "
3. Feed Schedule
" using the down-arrow key. Press the
right-arrow key.
Press the down-arrow key in order to select the
"4. Manual Mode"
menu then press the right-arrow key.
To Pause or Abort a Cycle:
-
Pause:
Select "Yes" to pause the
ongoing cycle. This function is only
available if a feed cycle is currently
running. Select "No" for the cycle to
restart the cycle from where it
stopped.
-
Abort:
Select "Yes" to abort the run-
ning feed cycle. This option only ap-
pears when a cycle is running.
To Start a Feed Cycle:
-
Manual Mode Status:
Before enabling a feed cycle, set the parameters below and then
set the status of the manual mode to "Yes". If a feed cycle is cur-
rently running, abort it before using the manual mode
Drop #x Blend :
Select the desired blend. If the controller doesn't use blends, this
value refers to the bin number.
Feed qty:
Select the amount of feed to be delivered to each drop.
4.4 House1, Manual
Current Cycle
Pause:
No
Abort:
No
Manual Mode
Status: Off
Drop #1
Blend:
1
Feed qty: 0kg
Drop #2 (...)