56
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
5.8.7 Scale Calibration
The scale must be calibrated regularly. To ensure the accuracy of
the scale, we recommend to check the scale's accuracy between
each flock.
Select "
9. Installation
" from the main menu using the up and down-
arrow keys. Press the right-arrow key.
Accessible from the installer mode only (s. 5.8.1).
Select the
"6. Scale Calibr."
menu
then press the right-arrow key. The
scale's calibration weight flashes on
the display.
Set the calibration weight to the de-
sired value using the adjustment but-
tons. Once this is done, press the down-
arrow key.
Make sure the scale is stable and empty
then press the down-arrow key to se-
lect the
"Scale is:"
menu. Press "+".
The message
"Laden"
is then
displayed. Put the calibration weight
in the feed scale hopper and wait until
the scale becomes stable again. We
recommend using a precision weight
of 10kg ±250mg.
Once the scale is stable again, save
the calibration by pressing the "+".
button. The message "
Saved
" is dis-
played during 2 seconds then returns
to the message "
Empty
" again. The
scale calibration is now completed.
9. Installation
6. Scale calibration
Scale 1
Calib weight: 10.00
Push + for next step
Scale is: Empty
Scale 1
Calib weight: 10.00
Push + for next step
Scale is: Laden
Scale 1
Calib weight: 10.00
Push + for next step
Scale is: Saved
17
TARGET FEED MASTER RF
TARGET FEED MASTER RF rev.09
FeedWeigher for
Breeders V.X.X
9. Installation
9. Installation
1. Settings
9. Installation
2. Scale Settings
Actual Weight: 0.00
Max Batch:
20kg
Prox Switch ?
Yes
Stability tol:
50
Valve
Auto
Empty time
1:00
9. Installation
3. Drop Settings
9.3 Drop Settings
1. Drop 1
2. Drop 2
9.3.1 Drop 1
Output Auger:
1
House:
2
Run Time: 1:00(m:s)
Animal Type:
Fem
9. Installation
4. Relay Assign.
9.4 Relay Assign.
1. Bin Augers
2. Output Augers
3. Drop Relays
4. Time Clock Rlys
5. Mixing Relay
9.4.2 Bin Relays
Bin 1 Auger
Mod: 2 Rly 2
9. Installation
5. Bin Setting
9.4 Relay Assign.
6. ID. Assignment
Module ID Assignment
ID#2 use relay
1-8
ID#3 use relay 1-16
ID#4 use relay 17-32
9.5 Bin Setting
1. Bin 1
2. Bin 2
9.5.1 Bin 1 Settings
Max fill time:
15
Re-order point: 100
Alarm if empty:
No
Backup bin:
3
FeedWeigher for
Breeders V.X.X
10. Password
10. Password
Current mode
User
9.1 Inst. Settings
# of bins:
6
# of houses:
2
# output aug.:
4
# of blends:
8
# of drops:
20
Feed cycles:
2
# time clocks:
8
With Valve ?
Yes
Units:
kg
Feed qty:
/100
Use Mixer:
No
Mix Time: 1:00(m:s)
Mix each batch:
No
Substitution:
Yes
Time of reset: 0:00
Shutoff augers on
run time alarm?
No