background image

EN 

© Adam Equipment Company 

2018

1

 

Adam Equipment 

HIGHLAND SERIES 

(Includes HCB xxxM EU & NTEP approved models)       

(HCB Software ver. 2.33 or higher – standard models)   

(HCB‐M Software. rev 2.39   – EU approved models)     

(HCB‐aM Software rev. 3.11  – NTEP approved models) 

99 Washington Street 
Melrose, MA 02176 
Phone 781-665-1400
Toll Free 1-800-517-8431

Visit us at www.TestEquipmentDepot.com

Summary of Contents for HCB 1002

Page 1: ...EU NTEP approved models HCB Software ver 2 33 or higher standard models HCB M Software rev 2 39 EU approved models HCB aM Software rev 3 11 NTEP approved models 99 Washington Street Melrose MA 02176 P...

Page 2: ...am Equipment Company 2018 2 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and...

Page 3: ...UNCTIONS 11 5 1 PERCENTAGE WEIGHING 11 5 2 PARTS COUNTING 11 5 3 ACCUMULATION 12 6 0 PARAMETERS 14 6 1 ENABLING WEIGHING UNITS 14 6 2 SETTING THE BACKLIGHT AND AUDIBLE ALERT BEEP 16 6 3 SETTING THE PR...

Page 4: ...se read the instruction manual and operate with caution to avoid hazard NOTE External metal parts and connectors are not linked to earth NTEP Approved models HCB aM have calibration controlled by jump...

Page 5: ...his key will move the flashing digit to the right Smpl Use this key to enter parts counting mode from the normal weighing mode When in parts counting pressing the Smpl will return to weighing mode Cle...

Page 6: ...scharge time is approximately 24 hours depending on the usage of the backlight The display will show an indication when the battery needs to be charged To charge the battery plug in the DC adapter at...

Page 7: ...u should disconnect the power supply if it is not going to be used for an extended period Keep free from vibration Do not place near heavy or vibrating machinery Avoid high humidity that might cause c...

Page 8: ...them easily on top of each other To save space and protect them from damage Without Shield With Shield Note Only models equipped with a 4 7 120mm pan can be stacked for storage Core CQT models with th...

Page 9: ...rectly and that there is no weight on the pan or the internal calibration weight not approved models has not been left in the calibrate position Move the lever all the way to the left Turn off the bal...

Page 10: ...function 4 3 WEIGHING To determine the weight of a sample first tare an empty container if used then place the sample in the container The display will show the weight of the sample and the unit of we...

Page 11: ...increments and the balance is set to 100 the display will show 100 00 However a small change of weight will cause the display to jump to 102 13 as one balance division 0 5g increase to 24 0g will be e...

Page 12: ...he balance is set for automatic accumulation see Parameters 6 3 Setting the Printer Parameters Accumulation the weight will be added to the memory when the balance becomes stable When the balance is s...

Page 13: ...hts have been added To view the totals in memory press the Print key when the balance is at zero The display will show ACC xx where xx is the total number of readings and the total weight before retur...

Page 14: ...ON F1 EL See section 6 2 Sets the backlight and audible alert beep SW ver 2 5 onwards F2 SEr See section 6 3 Sets the print parameters F3 oFF See section 6 4 Sets the auto power off parameter F4 SEt S...

Page 15: ...andard weighing unit in UK USA 0 0022046 Lb Ounce Avoirdupois ounce 16 ounces make a pound 0 035274 oZ Drams An ancient unit of weight Equal to 1 16th of an ounce 0 564383 d Grains A basic weighing un...

Page 16: ...e balance 2 After a few seconds the display will show the first function F1 UNT 3 Press the Mode key to select F2 EL 4 Press the 0 T key once to view the current settings for the backlight and twice t...

Page 17: ...umulation when the Print key is pressed P2 Con Data is sent continuously Accumulation is disabled P3 AUT The weighing results will be sent to the communication port automatically whenever a stable rea...

Page 18: ...There are 2 settings that the Highland can work with as follows FOr 1 Data format is with line headings and extra line feeds as shown in section 9 3 FOr 2 Data format is weight only Press the Mode ke...

Page 19: ...LS You can select if the internal mass or an external mass is to be used to calibrate the balance 1 To set this parameter press the Mode key during self checking test when turning on the balance 2 Aft...

Page 20: ...rrent value with the first digit flashing To change the value press to shift the position press Mode to increase the value and press Print to decrease the value The internal calibration weight should...

Page 21: ...EO n STA Stability symbol range 0 to 5 0 is the smallest stability range and 5 is largest 2 STA n ZTR Weight Tracking Range 0 to 5 3 ZTR Press the 0 T key to view the current settings To change the se...

Page 22: ...n as shown below To calibrate the handle is pushed to the side to lower the calibration mass INTERNAL CALIBRATION USING HANDICALTM 1 Press the on off key to turn the power on 2 Press the Smpl and Prin...

Page 23: ...ollows Model HCB 123 HCB 153 HCB 302 HCB 602 HCB 602H Weight 1 60g 50g 100g 200g 200g Weight 2 120g 100g 200g 400g 400g Weight 3 150g 300g 600g 600g Model HCB 1002 HCB 1502 HCB 2202 HCB 3001 HCB 6001...

Page 24: ...he scale on Load cell damaged Electronics damaged Remove any weight from the stainless steel pan and turn the balance off and back on again Try calibrating the balance Err 9 A D count is not stable wh...

Page 25: ...6001 Maximum Capacity 1000 g 1500 g 2200 g 3000 g 6000g Readability 0 01 g 0 05 g 0 01 g 0 1 g 0 1 g Repeatability s d 0 02 g 0 1 g 0 02 g 0 2 g 0 2 g Linearity s d 0 03 g 0 15 g 0 03 g 0 3 g 0 3 g P...

Page 26: ...ESE VALUES ARE FOR GUIDE PURPOSES ONLY 9 2 COMMON SPECIFICATIONS Interface USB and RS 232 bi directional Stabilization Time 3 Seconds typical Operating Environment M 15 C to 35 C 59 F to 95 F Power su...

Page 27: ...ing operations parts counting or recalling of totals from memory will all be different All lines end with a carriage return and a line feed 0dH and 0aH in ASCII Format 1 Output The lines will include...

Page 28: ...at The scale can be controlled with the following commands The commands must be sent in upper case letters i e T not t T cr lf Tares the scale to display the net weight This is the same as pressing 0...

Page 29: ...y will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment Th...

Page 30: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful in...

Page 31: ...EN Adam Equipment Company 2018 31...

Page 32: ...M EQUIPMENT is an ISO 9001 2008 certified global company with more than 40 years experience in the production and sale of electronic weighing equipment Adam products are predominantly designed for the...

Reviews: