67
3.3.2 Connection
3.3.2.1 Connecting to the CMU or the EMU
The HCS-4886/87/88 series congress unit is equipped
with a 1.5-meter 6P-DIN cable with a standard male
connector. To connect to the HCS-4100/50 CMU or the
HCS-8300 EMU, just connect the male connector of
the first unit to the output of the main unit.
If there is a long distance between the congress unit
and the CMU (EMU), CBL6PS extension cable can be
used. One end is equipped with a 6P-DIN male
connector and the opposite end with a female
connector. Just connect the female connector of the
cable to the next congress unit, and connect the male
connector to the output of the main unit.
Figure 3.18 HCS-4886/87/88 series congress unit
connected to the CMU/EMU
Neither the replacement of congress units nor cable
faults between congress units will affect the other units
if “Closed Loop - Daisy Chain” connection topology is
selected. “Closed Loop - Daisy Chain” connection,
achieved by closing the loop of the daisy-chained units,
increases system reliability. To obtain “Closed Loop -
Daisy Chain” connection, just connect the last
congress unit back to the CMU or the EMU with a
CBL6PP extension cable (the cable features a 6P-DIN
male connector at each end). In HCS-4100/50 series
system, the congress main unit can realize a “Closed
Loop - Daisy Chain” connection, but only one –
extension units do not offer this feature.
Figure 3.19 “Closed Loop - Daisy Chain” connection
between the CMU and HCS-4886/87/88 series congress
units
3.3.2.2 Connection between congress units
All congress units of HCS-4100/50 system are
daisy-chained easily and conveniently by dedicated
6P-DIN cables.
When connecting to another congress unit, just
connect the 6P-DIN standard female connector on the
0.6-meter cable of the unit to the 6P-DIN standard male
connector on the1.5-meter cable of the next unit.
Figure 3.20 “Daisy-chain” connection between
HCS-4886/87/88 series congress units
Содержание HCS-4100/50 Series
Страница 46: ...33 Figure 2 10 Floor mode setting Normal Mode Figure 2 11 Floor mode setting Insert Mode...
Страница 47: ...34 Figure 2 12 Floor mode setting Sync Line Out1 Mixer...
Страница 58: ...45 3 2 2 Installation 3 2 2 1 Cutout Figure 3 3 Cutout of HCS 48U7 series flush mounted congress unit unit mm...
Страница 59: ...46 Figure 3 4 Cutout of HCS 48U8 series flush mounted congress unit unit mm...
Страница 60: ...47 Figure 3 5 Cutout of HCS 48U9 series flush mounted congress unit unit mm except HCS 48U9DFFF...
Страница 61: ...48 Figure 3 6 Cutout of HCS 48U9DFFF flush mounted congress unit unit mm...
Страница 62: ...49 3 2 2 2 Installation Figure 3 7 Installation of HCS 48U7 series flush mounted congress unit...
Страница 63: ...50 Figure 3 8 Installation of HCS 48U8 series and HCS 48U9 series flush mounted congress unit...
Страница 65: ...52 Figure 3 11 Disassembly caution of HCS 48U8 and HCS 48U9 series flush mounted congress unit...
Страница 130: ...117 Figure 3 43 Installation of HCS 4325U 50 congress unit unit mm...
Страница 143: ...130 Figure 3 57 Multi function connector connected to the HCS 4341 50 series congress unit...
Страница 155: ...141 Figure 3 72 Multi function connector connected to HCS 4841 42 43 series congress units...
Страница 168: ...154 3 12 3 Connection Figure 3 83 Connection of HCS 1030U Electronic Nameplate with HCS 48U8 series congress unit...
Страница 170: ...156 4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 4385U 50 Interpreter unit...
Страница 223: ...www taiden com TAIDEN INDUSTRIAL CO LTD Copyright by TAIDEN Last Revision 06 2013...