
9
1.4 Features
z
System reliability
System reliability, as described below, has always been
the guiding principle while designing HCS-4100/50
Fully Digital Congress System:
Dual congress main unit hot spare
System software imports the hot-spare dual
server structure by operating the main server and
the back-up server at the same time
Dual connection backup is implemented between
the HCS-4100MA/50 congress main unit and the
HCS-8300 series extension main unit via optical
fiber and Cat.5 cable
“Closed Loop - Daisy Chain” connection topology:
breakdown or replacement of a congress unit
and connection failure of a cable will not
influence other congress units
Built-in communication auto termination function
to prevent system collapse if the TCP/IP cable is
pulled out
Auto recovery function, supports PnP
If PC malfunction happens, the CMU will return to
control status automatically and take over control
of the meeting, ensuring continuation of the
meeting process
z
System technological progress
HCS-4100/50 Fully Digital Congress System - based
on TAIDEN originated independent intellectual property
rights digital processing and transmitting technologies
MCA-STREAM - adopts embedded hardware structure
based on high performance dual CPU. HCS-4100/50
application software is based on Client/Server and
hot-spare dual server structure. CMU and PC use
advanced TCP/IP protocol for communication, perfectly
integrated to benefit from modern technologies.
Furthermore, Conference Sign-in System and Central
Control System can be integrated into TAIDEN
HCS-4100/50 Fully Digital Congress System to provide
the first complete and efficient solution in the world.
z
System operability
CMU controls efficiently: basic microphone control,
simultaneous interpretation, video tracking, voting -
without the intervention of an operator.
With a PC and HCS-4100/50 application software,
more functions can be achieved, including enhanced
microphone control, simultaneous interpretation,
delegate information management, sign-in control,
meeting data management and distribution, voting
control and output audio processing. HCS-4100/50
application software can also be set up according to
user requirements.
HCS-4100/50 application software adopts
Client/Server structure - the process of the meeting is
controlled by the operator from any PC within the same
LAN. If PC malfunction occurs, CMU will return to
control status automatically and take over control of the
meeting, ensuring continuation of the meeting.
z
Fine extensibility
The interpreter unit of HCS-4100/50 has a maximum of
64 channels (including floor channel) and satisfies the
requirements of large-scale international meetings:
allocating a language for each channel, selecting a
channel, interlock facility. To avoid reciprocal
interference and crosstalk the language of each
channel can be released separately. The system
supports a maximum of 4096 congress units and an
infinite number of channel selectors.
HCS-4100/50 system is modular: just daisy-chain
HCS-4100/50 units to set-up a configuration. If extra
system capacity is needed, units can be connected
easily, starting from any access point.
z
Economical and convenient installation
In virtue of the fully digital techniques of HCS-4100/50
system, system installation becomes simple and
economical, especially in conjunction with the
economical and durable HCS-4100/50 system
dedicated 6-PIN cable (substitutable by shielded Cat.5
cable). The cable, suitable for the requirements of any
kind of meeting, transmits up to 64 high quality audio
signals, control data and information simultaneously.
Every delegate unit is assigned an individual ID for
convenient setup and perpetual prevention of double
ID.
Содержание HCS-4100/50 Series
Страница 46: ...33 Figure 2 10 Floor mode setting Normal Mode Figure 2 11 Floor mode setting Insert Mode...
Страница 47: ...34 Figure 2 12 Floor mode setting Sync Line Out1 Mixer...
Страница 58: ...45 3 2 2 Installation 3 2 2 1 Cutout Figure 3 3 Cutout of HCS 48U7 series flush mounted congress unit unit mm...
Страница 59: ...46 Figure 3 4 Cutout of HCS 48U8 series flush mounted congress unit unit mm...
Страница 60: ...47 Figure 3 5 Cutout of HCS 48U9 series flush mounted congress unit unit mm except HCS 48U9DFFF...
Страница 61: ...48 Figure 3 6 Cutout of HCS 48U9DFFF flush mounted congress unit unit mm...
Страница 62: ...49 3 2 2 2 Installation Figure 3 7 Installation of HCS 48U7 series flush mounted congress unit...
Страница 63: ...50 Figure 3 8 Installation of HCS 48U8 series and HCS 48U9 series flush mounted congress unit...
Страница 65: ...52 Figure 3 11 Disassembly caution of HCS 48U8 and HCS 48U9 series flush mounted congress unit...
Страница 130: ...117 Figure 3 43 Installation of HCS 4325U 50 congress unit unit mm...
Страница 143: ...130 Figure 3 57 Multi function connector connected to the HCS 4341 50 series congress unit...
Страница 155: ...141 Figure 3 72 Multi function connector connected to HCS 4841 42 43 series congress units...
Страница 168: ...154 3 12 3 Connection Figure 3 83 Connection of HCS 1030U Electronic Nameplate with HCS 48U8 series congress unit...
Страница 170: ...156 4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 4385U 50 Interpreter unit...
Страница 223: ...www taiden com TAIDEN INDUSTRIAL CO LTD Copyright by TAIDEN Last Revision 06 2013...