14
23. “LINE OUT 2”
(RCAx2 unbalanced output)
24. “LINE OUT 1”
(3-cord XLR balanced output)
25. “LINE IN 2”
(RCAx2 unbalanced input)
26. “LINE IN 1”
(3-cord XLR balanced input)
27. RS-232C port x 2
“COM” port is used for connecting to a central
control system for central controlling, as well as for
system diagnosis;
“TEST” port is used for updating and monitoring.
2.2 Installation
The CMU can be fixed in a standard 19-inch cabinet. The
CMU is equipped with a pair of fixing brackets
①
. First
unscrew the lateral screws
②
from the housing. Then
fasten the brackets with these screws and put the CMU
in the cabinet. Finally fix the four holes
③
up with
screws.
Figure 2.3 Installation of the CMU
In addition, 1U metal stripes are included as decoration
to be installed between the CMUs in the cabinet. It is
also good for the ventilation and cooling off. Fix up the
four holes
③
with screws.
Figure 2.4 Decoration of cabinet
Содержание HCS-4100/50 Series
Страница 46: ...33 Figure 2 10 Floor mode setting Normal Mode Figure 2 11 Floor mode setting Insert Mode...
Страница 47: ...34 Figure 2 12 Floor mode setting Sync Line Out1 Mixer...
Страница 58: ...45 3 2 2 Installation 3 2 2 1 Cutout Figure 3 3 Cutout of HCS 48U7 series flush mounted congress unit unit mm...
Страница 59: ...46 Figure 3 4 Cutout of HCS 48U8 series flush mounted congress unit unit mm...
Страница 60: ...47 Figure 3 5 Cutout of HCS 48U9 series flush mounted congress unit unit mm except HCS 48U9DFFF...
Страница 61: ...48 Figure 3 6 Cutout of HCS 48U9DFFF flush mounted congress unit unit mm...
Страница 62: ...49 3 2 2 2 Installation Figure 3 7 Installation of HCS 48U7 series flush mounted congress unit...
Страница 63: ...50 Figure 3 8 Installation of HCS 48U8 series and HCS 48U9 series flush mounted congress unit...
Страница 65: ...52 Figure 3 11 Disassembly caution of HCS 48U8 and HCS 48U9 series flush mounted congress unit...
Страница 130: ...117 Figure 3 43 Installation of HCS 4325U 50 congress unit unit mm...
Страница 143: ...130 Figure 3 57 Multi function connector connected to the HCS 4341 50 series congress unit...
Страница 155: ...141 Figure 3 72 Multi function connector connected to HCS 4841 42 43 series congress units...
Страница 168: ...154 3 12 3 Connection Figure 3 83 Connection of HCS 1030U Electronic Nameplate with HCS 48U8 series congress unit...
Страница 170: ...156 4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 4385U 50 Interpreter unit...
Страница 223: ...www taiden com TAIDEN INDUSTRIAL CO LTD Copyright by TAIDEN Last Revision 06 2013...