206
8.5.2 Earphone
EP-820AS single earphone
Cooperates with the infrared receiver or the
congress unit
Hi-Fi sound quality
32
Ω
, Ø 3.5 mm stereo jack
Frequency response: 50 Hz - 20 kHz
Sensitivity:
≥
102 dBA/1 mW
EP-828 single earphone
Cooperates with the infrared receiver or the
congress unit
Hi-Fi sound quality
32
Ω
, Ø 3.5 mm stereo jack (TRS, Ring: NC)
Frequency response: 20 Hz - 20 kHz
Sensitivity:
≥
108 dBA/1 mW
EP-950B interpreter headset
Incorporated with interpreter unit for monitoring
and speaking
Hi-Fi sound quality
32
Ω
× 2
,
Ø 3.5 mm stereo plug (TRS) for
headphone
Ø 3.5 mm stereo plug (TRS, Ring: NC) for
microphone
Frequency response of headphone: 20 Hz to 20
kHz
Sensitivity of headphone:
≥
108 dBA/1 mW
Frequency response of microphone: 50 Hz to 20
kHz
Sensitivity of microphone: -46 dBV/Pa
HCS-5100PA/PB headphone
Cooperates with the infrared receiver or the
congress unit
Hi-Fi sound quality
32
Ω
×2, Ø 3.5 mm stereo jack
Frequency response: 20 Hz - 20 kHz
Sensitivity:
≥
108 dBA/1 mW
8.5.3 Accessories
CBL6PS 6 pin dedicated extension cable
For extending the connection between the
congress system main unit and the congress
unit
One male plug at one end and one female
socket at the opposite end
Length: 3-meter, 5-meter, 10-meter, 20-meter,
30-meter, 40-meter and 50-meter
CBL6PP-02 dedicated 6-pin extension cable
For extending the connection between the
congress system main unit and the congress
unit
Male connector at both ends
2-meter
long
HCS-4352(T)/50 6PIN cable distribution unit
With relay function, for signal regeneration
6P-DIN interface with 1 input and 2 outputs, 1
input and 3 outputs
Input: 2-meter long 6P-DIN male plug
Output: 6P-DIN output, can drive 80-meter
extension cable
HCS-4340DDB/50 Data Distribution Board
HCS-4340DDB/50 is a printed circuit board. In
cooperation with a variety of digital devices, it
can be used to provide access to data
communication link of HCS-8300 and
HCS-4100/50 series
Hall
display
Driver
Open control protocol for external device remote
control
“Slow down” and “Help” indicating light control
2.1 m cable with 6P-DIN plug
PCB
connector
for
External initialization button and LED
indicator
8 bit parallel data output/input
Содержание HCS-4100/50 Series
Страница 46: ...33 Figure 2 10 Floor mode setting Normal Mode Figure 2 11 Floor mode setting Insert Mode...
Страница 47: ...34 Figure 2 12 Floor mode setting Sync Line Out1 Mixer...
Страница 58: ...45 3 2 2 Installation 3 2 2 1 Cutout Figure 3 3 Cutout of HCS 48U7 series flush mounted congress unit unit mm...
Страница 59: ...46 Figure 3 4 Cutout of HCS 48U8 series flush mounted congress unit unit mm...
Страница 60: ...47 Figure 3 5 Cutout of HCS 48U9 series flush mounted congress unit unit mm except HCS 48U9DFFF...
Страница 61: ...48 Figure 3 6 Cutout of HCS 48U9DFFF flush mounted congress unit unit mm...
Страница 62: ...49 3 2 2 2 Installation Figure 3 7 Installation of HCS 48U7 series flush mounted congress unit...
Страница 63: ...50 Figure 3 8 Installation of HCS 48U8 series and HCS 48U9 series flush mounted congress unit...
Страница 65: ...52 Figure 3 11 Disassembly caution of HCS 48U8 and HCS 48U9 series flush mounted congress unit...
Страница 130: ...117 Figure 3 43 Installation of HCS 4325U 50 congress unit unit mm...
Страница 143: ...130 Figure 3 57 Multi function connector connected to the HCS 4341 50 series congress unit...
Страница 155: ...141 Figure 3 72 Multi function connector connected to HCS 4841 42 43 series congress units...
Страница 168: ...154 3 12 3 Connection Figure 3 83 Connection of HCS 1030U Electronic Nameplate with HCS 48U8 series congress unit...
Страница 170: ...156 4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 4385U 50 Interpreter unit...
Страница 223: ...www taiden com TAIDEN INDUSTRIAL CO LTD Copyright by TAIDEN Last Revision 06 2013...