3.2 Conditions for air conditioning equipment
The conditions required for a high-performance air conditioner are the following.
Refrigerant vaporizes at the lowest temperature possible.
Refrigerant liquefies easily.
The largest possible quantity of refrigerant vaporizes in the evaporator.
1. When we look at the conditions of the refrigerant
within the refrigeration cycle, we find that the
refrigerant which was compressed by the
compressor becomes a high-temperature
high-pressure gas.
2. The refrigerant next enters the condenser, where
it is cooled and changed from gas to liquid form as
it passes through. All of the refrigerant must be
changed to liquid form when it reaches the
condenser outlet. If the condenser cooling is
insufficient, some refrigerant remains in gas form,
and will result in degraded cooling performance.
3. When the liquid refrigerant passes through the
expansion valve, it is atomized.
The expansion valve is also known as a throttle
valve. It sprays the high-pressure liquid through a
small nozzle to create a refrigerant mist. This
allows the refrigerant to vaporize easily.
4. In the evaporator, the refrigerant mist absorbs
heat from the cab and vaporizes rapidly. By the
time it reaches the evaporator outlet, the
refrigerant has been completely transformed to a
vapor.
5. If the amount of refrigerant is insufficient, it
completely evaporates in the middle as it passes
through the evaporator. This results in degraded
performance of the evaporator.
6. On the other hand, if there is too much refrigerant,
it cannot vaporize in the evaporator, and some
remains in liquid form when it enters the
compressor. If this occurs, there is the possibility
that compressing liquid instead of vapor will
damage the compressor.
7. For these reasons, the amount of refrigerant must
be adjusted according to meet a variety of
conditions.
8. The purpose of the air conditioner is to provide a
comfortable environment not only by lowering the
cab temperature, but also by reducing the
humidity. This is accomplished by cooling the hot
air in the cab, and condensing the moisture in it
when it passes the evaporator.
9. In this way, the moisture in the air is removed,
reducing the humidity. The water droplets that
adhere to the fins are led to the outside of the
vehicle through a hose.
Содержание TT-800XXL1
Страница 20: ...B 2 B 2 Hydraulic Pump 3 W101 0280E 1 2 Inside view Variable displacement piston pump...
Страница 25: ...8 W101 0280E B 2 B 2 Hydraulic Pump 1 Joint control piston 2 Hanger 3 Metal 4 Orifice Hanger section 6 7...
Страница 114: ...5 G 2 G 2 Boom Five Section Boom 5 W536 0760E G 2...
Страница 166: ...13 13 W701 0160E K 2 K 2 Air Conditioner K 2 4 Layout 4 1 Overall layout...
Страница 167: ...14 14 W701 0160E K 2 K 2 Air Conditioner K 2 4 2 Overall layout...
Страница 168: ...15 15 W701 0160E K 2 K 2 Air Conditioner K 2 4 3 Evaporator section...
Страница 169: ...16 W701 0160E K 2 K 2 Air Conditioner 5 Compressor ass y...
Страница 170: ...17 17 W701 0160E K 2 K 2 Air Conditioner K 2 6 Evaporator ass y...
Страница 171: ...18 18 W701 0160E K 2 K 2 Air Conditioner K 2 7 Condenser ass y...
Страница 172: ...19 19 W701 0160E K 2 K 2 Air Conditioner K 2 8 Electric 8 1 Electric circuit 0 363 205 60030...
Страница 173: ...20 20 W701 0160E K 2 K 2 Air Conditioner K 2 8 2 Main harness A...
Страница 174: ...21 21 W701 0160E K 2 K 2 Air Conditioner K 2 8 3 Main harness B...
Страница 227: ...Hydraulic Pressure Setting Table 1 WY02 0320E 1 Y 1 Y 1 Y 1 Hydraulic Pressure Setting Table 1 345 801 01500...
Страница 254: ...Location of Hydraulic Parts 4 WZ07 0780E 4 Z 4 Z 4 Z 4 Location of Hydraulic Parts...
Страница 259: ...Hydraulic Electric Carrier Equipment Comparison Table Z 8 Z 8 Z 8 9 WZ09 0130E 9...
Страница 262: ...Z 11 Z 11 Harness Swing Table Right Z 11 11 WZ04 1300E 11 Harness Swing Table Right 5 343 530 32010...
Страница 263: ...Z 12 Z 12 Harness Boom Z 12 12 WZ04 1310E 12 Harness Boom 1 2 2 343 530 32040 1 343 530 22030...
Страница 265: ...14 WZ04 1320E 14 Z 14 Z 14 Harness Lower Z 14 Harness Lower Applicable serial No 475334 1 1 336 500 30021...
Страница 266: ...Z 15 Z 15 Harness Outrigger Operation Option Z 15 15 WZ04 1330E 15 Harness Outrigger Operation Option 0 333 316 60020...