K-2
K-2
Air Conditioner
26
W701-0160E
10.2 How to charge air conditioner gas
Flow
No.
Procedure Safety
point
Jigs and
tools
1
Plug the power supply cord of the main unit.
2
Connect the coupler of the high-pressure side (red hose) and the
low-pressure side with the compressor main body sequentially.
Purge residual pressure before connecting because the
connection of coupler becomes firm if there is residual pressure in
the unit.
(Usually it has been performed at work end. Refer to Flow No.16.)
Be careful to the
scaffold
3
Attach one freon can.
(Put the blind caps to the couplers which gas-can has not been
attached.)
Tighten as it is though the gas leaks a little when attaching.
Be careful that gas
liquor does not splash
4
Set the time switch to the position of gas replenishment.
5
Turns the power switch to the manual side. (with 3 seconds
automatic air purge)
6 Start
the
engine.
- Engine speed: Idling
- Temperature control: Maximum cool
- Blower: Lo-Hi
Make sure to check
surroundings
7
Check the condition of bubble in the sight glass. (Check whether
the bubble disappears.)
Make sure to check
surroundings
8
Turn OFF the power switch when the gas disappears from the
remainder gas sight glass of the main unit.
Be careful to the
scaffold
9
Detach the empty gas can, and attach another gas can.
Be careful that gas
liquor does not splash
10
Turns the power switch to the manual side. (with 3 seconds
automatic air purge)
- Repeat Flow No.7 until the bubble disappears.
(The charging amount should be 200g
±
50g after the bubble
disappears.)
11
Turn OFF the power switch when the gas disappears from the
remainder gas sight glass of the main unit.
12
Check the air-conditioning capability
Temperature control: : Maximum cool
Blower: : Hi
Engine speed : Approx. 2000 rpm
The blowing temperature must be in the graphic chart value.
(Refer to the graphic chart.)
(Near the outside air temperature scale in the gauge is a standard
pressure.)
13
Stop the engine
Pull out the key
14
Wait for two minutes until pressure falls, and detach the
high-pressure side and low-pressure side quick couplers.
Be careful to the
scaffold
15
Test gas leakage. (for all hose connections)
(Check the gas leakage from the lower side because the freon is
heavier than air.)
Compressor: 2 places
Compressor charge coupler: 2 places
Receiver: 2 places
Condenser Assy: 2 places
Main body of air conditioner: 2 places
Pressure switch hose connections : 1 place
11 places in total
Be careful to the
scaffold
Gas
leak
tester
Содержание TT-800XXL1
Страница 20: ...B 2 B 2 Hydraulic Pump 3 W101 0280E 1 2 Inside view Variable displacement piston pump...
Страница 25: ...8 W101 0280E B 2 B 2 Hydraulic Pump 1 Joint control piston 2 Hanger 3 Metal 4 Orifice Hanger section 6 7...
Страница 114: ...5 G 2 G 2 Boom Five Section Boom 5 W536 0760E G 2...
Страница 166: ...13 13 W701 0160E K 2 K 2 Air Conditioner K 2 4 Layout 4 1 Overall layout...
Страница 167: ...14 14 W701 0160E K 2 K 2 Air Conditioner K 2 4 2 Overall layout...
Страница 168: ...15 15 W701 0160E K 2 K 2 Air Conditioner K 2 4 3 Evaporator section...
Страница 169: ...16 W701 0160E K 2 K 2 Air Conditioner 5 Compressor ass y...
Страница 170: ...17 17 W701 0160E K 2 K 2 Air Conditioner K 2 6 Evaporator ass y...
Страница 171: ...18 18 W701 0160E K 2 K 2 Air Conditioner K 2 7 Condenser ass y...
Страница 172: ...19 19 W701 0160E K 2 K 2 Air Conditioner K 2 8 Electric 8 1 Electric circuit 0 363 205 60030...
Страница 173: ...20 20 W701 0160E K 2 K 2 Air Conditioner K 2 8 2 Main harness A...
Страница 174: ...21 21 W701 0160E K 2 K 2 Air Conditioner K 2 8 3 Main harness B...
Страница 227: ...Hydraulic Pressure Setting Table 1 WY02 0320E 1 Y 1 Y 1 Y 1 Hydraulic Pressure Setting Table 1 345 801 01500...
Страница 254: ...Location of Hydraulic Parts 4 WZ07 0780E 4 Z 4 Z 4 Z 4 Location of Hydraulic Parts...
Страница 259: ...Hydraulic Electric Carrier Equipment Comparison Table Z 8 Z 8 Z 8 9 WZ09 0130E 9...
Страница 262: ...Z 11 Z 11 Harness Swing Table Right Z 11 11 WZ04 1300E 11 Harness Swing Table Right 5 343 530 32010...
Страница 263: ...Z 12 Z 12 Harness Boom Z 12 12 WZ04 1310E 12 Harness Boom 1 2 2 343 530 32040 1 343 530 22030...
Страница 265: ...14 WZ04 1320E 14 Z 14 Z 14 Harness Lower Z 14 Harness Lower Applicable serial No 475334 1 1 336 500 30021...
Страница 266: ...Z 15 Z 15 Harness Outrigger Operation Option Z 15 15 WZ04 1330E 15 Harness Outrigger Operation Option 0 333 316 60020...