WEB Interface
75
ID: um_tsmux
CP525 cMux User’s Manual Rev. 5.20.12 (3944)
Configuration ID
Configure a user defined name for the current configuration of the unit. This name will, if
given, be diplayed in brackets after the unit name in the status header as shown in
. The
Configuration ID
does not, as opposed to the
Name
and
Inventory ID
fields, remain
untouched when loading a new unit configuration. Loading a new unit configuration will
change the
Configuration ID
. See
on how to load a new configuration.
Product name
Displays the name of the product as designated by T-VIPS.
Serial number
The serial number of the device.
Software version
The version of the software currently installed on the device. The software version is given
by the following syntax:
<
major_version
>
.
<
minor_version
>
.
<
patch_version
>
The convention for the SW version numbering is as follows:
major_version
Incremented for significant SW changes.
minor_version
Incremented for minor changes. The minor version number is even for official retail
releases and odd for beta releases.
patch_version
If minor_version is even, patch_version gives the patch level of that version. A patch
level of zero means the SW is built on the latest code base, an even patch_version
means this is a released SW patch on a previous release. An odd patch_version means
that this is a test version. If minor is odd, this is a beta version, and the patch_version
simply gives the build number.
Software build time
Reports the time of which the current release image was built.
Device up time
The amount of time that has passed since the device was last reset.
Internal temperature
This shows the current internal temperature of the unit in degrees Celsius and Fahrenheit.
Fan speed
This bar chart shows the current speed of the device fans relative to full speed.
Flash Power LED button
The
Flash Power LED
button activates flashing the green power LED on the device in
question. This is useful for identifying which device is currently being configured. Each
click of the button extends the blinking period by five seconds up to a maximum of about
30 seconds of blinking.
Содержание CP525 cMux
Страница 1: ...CP525 cMux User s Manual Revision 5 20 12 3944 2012 12 17 Valid for SW version 5 20 12 and newer ...
Страница 2: ......
Страница 10: ......
Страница 12: ...12 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 18: ...18 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 24: ...24 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 66: ...66 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 238: ...238 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 248: ...248 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 276: ...276 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...