WEB Interface
199
ID: um_tsmux
CP525 cMux User’s Manual Rev. 5.20.12 (3944)
Mode
How to handle this specific table. The options depend on the type of table. Double-click
on the table cell to open the pull-down list of selections.
Stopped
The table will not be present on the output unless mapped through manually on the
PIDs page.
Passthrough PID
The well-known table PID is passed through directly from the selected input.
Passthrough Remap
The user specifies a PID value and source port, and this elementary stream will be
remapped to the well-known table PID in the output. This mode can be used to
remap an unsignalled PID on any input port to the well-known PID in the output.
Playout Unchanged
The complete table is collected from the input data base of the selected input and
played out as is. For PMT this means that all PMT sections on the input are posted
for playout, and likewise for EITpfa. This mode is typically used for forwarding of
BAT and SI-other tables (SDTo, NITo, EITpfo, EITso), while the SI-actual tables are
set to "Playout Regenerated". For PSIP tables other than TVCT/CVCT, this is the only
supported playout mode. (Note that it is also possible to configure pass-through for
the tables in the PSIP base PID 8187).
Playout Downloaded
This mode is used in conjunction with the SI/PSIP Download server described in
. The tables are retrieved from the download database and played out
unchanged.
Playout Event DB
This mode is used in conjunction with the Dynamic PSIP feature. When choosing this
mode the tables will be played out from the tables received through this Dynamic
PSIP interface.
Playout Regenerated
Regenerate mode is used for tables that need to be totally rebuilt due to changes in
the service configuration.
Playout Static
This mode is used in conjunction with the "Static SI Configuration" described in
. The tables are retrieved from the static si database and played out
unchanged.
Playout Internal
Used in order to generate TDT/TOT from the internal real time clock.
Interval
Playout interval in any playout mode, in milliseconds.
Содержание CP525 cMux
Страница 1: ...CP525 cMux User s Manual Revision 5 20 12 3944 2012 12 17 Valid for SW version 5 20 12 and newer ...
Страница 2: ......
Страница 10: ......
Страница 12: ...12 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 18: ...18 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 24: ...24 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 66: ...66 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 238: ...238 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 248: ...248 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 276: ...276 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...