![T-VIPS CP525 cMux Скачать руководство пользователя страница 148](http://html1.mh-extra.com/html/t-vips/cp525-cmux/cp525-cmux_user-manual_3088830148.webp)
148
WEB Interface
CP525 cMux User’s Manual Rev. 5.20.12 (3944)
ID: um_tsmux
is found the regulator switches to
Coarse
mode where the output bitrate is coarsely moved
closer to the new rate. From
Coarse
mode the regulator enters
Finetune
mode.
Initial bitrate
Here the exact initial bitrate found is displayed.
Current bitrate
This parameter shows the exact bitrate played out on the ASI port at the moment.
Measured bitrate
This parameter is an input to the regulator in the
Rate Estimation
and
Coarse
phases, and
shows the bitrate measured for the data stream since last re-sync. In the first minutes after
a re-sync this measurement depends on IP network jitter and is highly inaccurate. After a
few minutes of operation the value gets more and more accurate and can be compared to
the current bitrate to see how far off the target bitrate the regulator is operating.
Regulator output
Indicates the amount of correction the regulator must apply to the output bitrate, with
respect to the initially measured input bit rate, in order to avoid buffer under-/overflow.
Regulator operation range
Indicates the maximum clock correction (in ppm) that may be applied. This parameter
is affected by the “Expected PCR accuracy” parameter and is typically configured slightly
wider to allow headroom for buffer regulation.
Channel uptime
The elapsed time since last re-synchronisation occurred.
Number of re-synchs
Displays the number of re-synchronisations since the last unit power up, or since the
Reset
Stats
function was last used (see
).
8.6.2.4 Copy
This tab is only visible if a Copy Input is selected in the Input Navigator.
The
Main Configuration
contains the following fields:
Enable input
If enabled, the Copy Input will receive packets from the Source Input.
Source input
Select the Source input, from where the packets will be copied. By clicking on the icon to
the right of the field, a list will pop up with all allowed Source inputs on the unit.
Input label
Custom label for the selected input.
The remainder of the page is similar to that of other input types, but lacks any physical prop-
erties.
Содержание CP525 cMux
Страница 1: ...CP525 cMux User s Manual Revision 5 20 12 3944 2012 12 17 Valid for SW version 5 20 12 and newer ...
Страница 2: ......
Страница 10: ......
Страница 12: ...12 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 18: ...18 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 24: ...24 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 66: ...66 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 238: ...238 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 248: ...248 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 276: ...276 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...