![T-VIPS CP525 cMux Скачать руководство пользователя страница 275](http://html1.mh-extra.com/html/t-vips/cp525-cmux/cp525-cmux_user-manual_3088830275.webp)
Forward Error Correction in IP Networks
275
ID: um_tsmux
CP525 cMux User’s Manual Rev. 5.20.12 (3944)
Figure B.11
FEC latency and buffer size
Also shown is the resulting overhead and the number of packets that can be corrected. In
column-only FEC there is one FEC packet per column, resulting in a 1/D increase in transmission
overhead, D being the matrix column depth. I.e. in a 10 row matrix (D=10) the added overhead
is 10%. The minimum allowable column depth of 4 will produce 25% overhead.
In two-dimensional FEC there will be D+L FEC packets in a DxL matrix (L being the row
length). Thus the added overhead is D+L/DxL, which for a 10 by 10 matrix amounts to 20%.
Adding row-FEC will increase the error correcting capability without significantly increasing the
latency or buffer size requirement. Applying row- and column-FEC also enables use of iterative
FEC calculations to recover more missing packets. The equipment manufacturer is at liberty to
determine the algorithm used in error recovery as long as the requirements and limitations of
the specification are respected.
Содержание CP525 cMux
Страница 1: ...CP525 cMux User s Manual Revision 5 20 12 3944 2012 12 17 Valid for SW version 5 20 12 and newer ...
Страница 2: ......
Страница 10: ......
Страница 12: ...12 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 18: ...18 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 24: ...24 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 66: ...66 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 238: ...238 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 248: ...248 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 276: ...276 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...