WEB Interface
155
ID: um_tsmux
CP525 cMux User’s Manual Rev. 5.20.12 (3944)
Horisontally, the bar chart shows the current rate and the minimum and maximum rates mea-
sured for each packet stream. The blue bar shows the current rate. The grey bar shows minimum
and maximum rates. Holding the mouse cursor over a bar shows a tool tip with the rates as a
numeric value.
To the right of the chart a field of options are provided to configure the view. The
Sort by
drop
down menu on top lets the user sort the bar chart by different parameters. The
Filtering
frame
lets the user choose which PIDs to show. Checking the
Hide null PID
check box removes the
null PID from the chart. Unchecking any of the other check boxes removes the corresponding
PIDs from the chart.
Below the
Filtering
frame the
Reset min/max bitrates
button is provided. Hitting this button
resets the min and max rates counters of all PIDs.
8.6.2.7 Tables
The Tables page shows detailed information about all the tables that are currently residing in
the input SI/PSIP database of the device. Accessing the related sub pages gives access to table
contents right down to byte level.
Which tables being currently analysed by the device is also displayed.
“Tables” tab
The button switches to a detailed view of the tables present on the input and analysed by
the device.
“Settings” tab
This button switches to a page showing what tables are being analysed.
“Sources” tab
This button switches to a page allowing the user to configure non-default source PID of
SI/PSIP tables.
The
Tables
sub page is shown in figure
Figure
shows the table details in list view.
The left hand side of the page contains a tree showing the tables that are present on the input
and analysed by the device. The tables belonging to a specific folder are displayed to the right
by clicking on the folder.
Above the table the following information and buttons can be found:
Shown tables
The number of table that fall into the chosen folder compared to the total number of tables.
Show ID’s as
Configure to view id’s and keys in hexadecimal or decimal notation.
The right hand side table of the sub page has the following columns:
Table
The type of information table and (in braces, []) the PID containing it.
Содержание CP525 cMux
Страница 1: ...CP525 cMux User s Manual Revision 5 20 12 3944 2012 12 17 Valid for SW version 5 20 12 and newer ...
Страница 2: ......
Страница 10: ......
Страница 12: ...12 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 18: ...18 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 24: ...24 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 66: ...66 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 238: ...238 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 248: ...248 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Страница 276: ...276 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...