SV106A User Manual
Contact force level logging
In case SV 105AF is used it is possible
to log and display force levels. The
Force 1-3/4-6 Logger
list enables the
user to select which parameters of force
level will be recorded to the logger file,
available in the plot and to select its
colours.
The force results in Newtons will be
visible in Logger and Dosimeter
presentation modes.
<ENT>
5.6.3 Logger trigger parameters setup
– Logger Trigger
The
Logger Trigger
position appears
only in the advanced instrument mode
(
path: <Menu> / Auxiliary Setup /
Instrument Mode: Advanced Mode
).
The
Logger Trigger
parameters define
the way the measurement results are
saved in the logger.
Logger Trigger
switches on the result logging.
<ENT>
The logger triggering of the measurements (
Enabled
) can be switched on
by means of the
<
>
push-button.
In the
Logger Trigger
sub-list the user may switch off or on (
Enabled
) the
logger triggering, determine the parameters of the triggering signal
(
Trigger Parameters
), select the number of the results saved in the logger
before the fulfilment of the triggering condition (
Pre
) and the number of the
results saved in the logger after the fulfilment of the triggering condition
(
Post
). If the triggering condition is fulfilled, the logger contains:
•
the measurement results registered directly before the fulfilment of the triggering condition. Time of this
recording can be calculated by multiplying the value set in the
Pre
position by the time period taken from
the
Logger Step
position (
path: Menu / Measurement / Data Logging / Logger Setup
);
•
all measurement results up to the moment the triggering condition disappears;
•
the results registered directly after the moment the triggering condition disappears. Time of this recording
can be calculated by multiplying the value set in the
Post
position by the time period taken from the
Logger Step
position (
path: Menu / Measurement / Data Logging / Logger Setup
).
Pre and post trigger recording
In the
Pre
/
Post
line the number of the
results recorded in the logger’s file
before/after
the
fulfilment
of
the
triggering condition can be set. This
number is within the limit 0..20 for
Pre
trigger and 0..200 for
Post
trigger.
=>
Trigger parameters setting
The
position
Trigger Parameters
enables the user to define
the
parameters of the triggering signal. To
open this position the user should select
it and press
<ENTER>
.
<ENT>