Chapter 2: Server Installation
SUPERSERVER 8048B-TRFT USER'S MANUAL
2-5 Rack Mounting Instructions
This section provides information on installing the SC848 chassis into a rack unit
with the rails provided. There are a variety of rack units on the market, which may
mean that the assembly procedure will differ slightly. You should also refer to the
installation instructions that came with the rack unit you are using.
Note:
This rail will fit a rack between 27” to 34.45" deep.
Identifying the Inner Rack Rails
The chassis package includes one pair of rack rail assemblies in the rack mounting
kit. Each assembly consists of an inner rail that secures to the chassis and an outer
rail that is attached directly to the rack.
Figure 2-1. Installing the Inner Rails
Inner Rail Assembly
Figure 2-2. Installing the Rails
Installing the Inner Rails on the Chassis
Installing the Inner Rails
1. The inner rails are etched with "L" (left side) and "R" (right side). Place one
inner rail on the side of the chassis, aligning the hooks of the chassis with the
inner rail holes. Make sure the rail faces "outward" so that it will fit with the
rack's mounting bracket.
2. Slide the rail toward the front of the chassis to hook the inner rail onto the
side of the chassis.
3.
Secure the chassis with two flat head M4 x 4mm screws as illustrated.
4. Repeat steps 1-3 for the other inner rack rail.
1
1
1
2
1
3
Warning:
do not pick up the server by the front handles. They are designed
to pull the system from a rack only.
Содержание SuperServer 8048B-TRFT
Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 8048B TRFT...
Страница 15: ...2 10 SUPERSERVER 8048B TRFT USER S MANUAL Notes...
Страница 29: ...4 20 SUPERSERVER 8048B TRFT USER S MANUAL Notes...
Страница 46: ...5 32 SUPERSERVER 8048B TRFT USER S MANUAL Notes...
Страница 52: ...6 10 SUPERSERVER 8048B TRFT USER S MANUAL Notes...
Страница 79: ...7 52 SUPERSERVER 8048B TRFT USER S MANUAL Notes...
Страница 81: ...A 2 SUPERSERVER 8048B TRFT USER S MANUAL Notes...