background image

USER'S MANUAL

Revision 1.0a

SuperServer

8048B-TRFT

Содержание SuperServer 8048B-TRFT

Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 8048B TRFT...

Страница 2: ...property of Supermicro and or its licensors and is supplied only under a license Any use or reproduction of this product is not allowed except as expressly permitted by the terms of said license IN N...

Страница 3: ...procedures given in this chapter when installing removing or reconfiguring SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter inclu...

Страница 4: ...into a Rack 2 8 SUPERSERVER 8048B TRFT USER S MANUAL vii Removing the Chassis from the Rack 2 9 Chapter 3 System Interface 3 1 Overview 3 1 3 2 Control Panel Buttons 3 2 Power 3 2 Reset 3 2 3 3 Contr...

Страница 5: ...5 30 5 14 Onboard Battery 5 31 Chapter 6 Advanced Chassis Setup 6 1 Static Sensitive Devices 6 1 Precautions 6 1 6 2 Control Panel 6 2 6 3 Installing Hard Drives 6 3 6 4 Accessing the Inside of the S...

Страница 6: ...er as listed below Four passive heatsinks SNK P0048PS One air shroud MCP 310 41804 0B Four 9 cm cooling fans FAN 0146L4 Three 8 cm rear exhaust fans FAN 0148L4 One SATA backplane BPN SAS 846A Twenty f...

Страница 7: ...port RAID 0 1 5 and 10 The SATA drives are hot swappable units PCI Expansion Slots The X10QBi serverboard has four PCI Express 3 0 x16 slots and seven PCI Express 3 0 x8 slots 1 3 Server Chassis Featu...

Страница 8: ...wer Connector Power Connector Power Connector Power Connector Power Connector Power Connector Power Connector Power Connector SMI2 CH0 2 66GT s SMI2 CH1 2 66GT s SMI2 CH2 2 66GT s SMI2 CH3 2 66GT s SM...

Страница 9: ...m Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supe...

Страница 10: ...enerated The system needs to be placed near a grounded power outlet Be sure to read the Rack and Server Precautions in the next section 2 3 Preparing for Setup The box your chassis was shipped in shou...

Страница 11: ...ronment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated a...

Страница 12: ...hat secures to the chassis and an outer rail that is attached directly to the rack Figure 2 1 Installing the Inner Rails Inner Rail Assembly Figure 2 2 Installing the Rails Installing the Inner Rails...

Страница 13: ...t to the rear side of the outer rail with three M5 screws and washers Keep the screws slack so that they may be adjusted later 4 Repeat steps 1 3 for the left outer rail Figure 2 3 Assembling the Oute...

Страница 14: ...Insert and tightening the thumbscrews that hold the front of the server to the rack 1 A 1 B Note figures are for illustrative purposes only Always install servers into racks from the bottom up Figure...

Страница 15: ...2 10 SUPERSERVER 8048B TRFT USER S MANUAL Notes...

Страница 16: ...several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components...

Страница 17: ...d to reboot the system 3 3 Control Panel LEDs The control panel located on the left handle of the SC848 chassis has five LEDs These LEDs provide you with critical information related to different part...

Страница 18: ...rier LEDs Each hard drive carrier has two LEDs Blue Solid on Drive is present and available Blinking Drive is actively being accessed Each drive carrier has a blue LED When illuminated in a solid on s...

Страница 19: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 20: ...artado de traducciones que acompa a a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE S CURIT Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation...

Страница 21: ...e that the protective device is rated not greater than 250 V 20 A Waarschuwing Raadpleeg de installatie instructies voordat u het systeem op de voedingsbron aansluit 250 V 20 A Warnung Dieses Produkt...

Страница 22: ...eiliging overspanning van uw electrische installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V 20A Advertencia El sistema debe ser disconnected de todas las fuentes...

Страница 23: ...confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Waarschuwing Deze apparatuur mag alleen worden ge nstalleerd vervangen of hersteld d...

Страница 24: ...semblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera inc...

Страница 25: ...Warnung Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje...

Страница 26: ...roduct Disposal Warning Ultimate disposal of this product should be handled according to all national laws and regulations Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de...

Страница 27: ...ousing Hot Swap Fan Warning Warnung Die L fter drehen sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenst nde von den ffnungen des...

Страница 28: ...hlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle anderen elektrischen Ger t...

Страница 29: ...4 20 SUPERSERVER 8048B TRFT USER S MANUAL Notes...

Страница 30: ...ery carefully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to pr...

Страница 31: ...Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that move...

Страница 32: ...ress and release the load lever labeled Open 1st OPEN1st Press down on load lever labeled Open 1st OPEN1st Connecting the Control Panel JF1 contains header pins for various front control panel connect...

Страница 33: ...open the load plate 6 Once they are aligned carefully lower the CPU straight down into the socket Do not drop the CPU on the socket Do not move the CPU horizontally or vertically To avoid damaging th...

Страница 34: ...erboard and the heatsink bracket underneath 3 Screw in two diagonal screws i e the 1 and the 2 screws until just snug to avoid possible damage to the CPU do not over tighten the screws 4 Finish the in...

Страница 35: ...DIMM2D_LED4 DIMM1D_LED3 DIMM0D_LED2 BAR CODE A3 D1 D2 C1 C2 C3 D3 OK B1 B2 B3 A1 A2 JDI JDI DIMMC3 DIMMA1 DIMMA2 DIMMA3 DIMMB3 DIMMB2 DIMMB1 Rev 1 01 DIMMC2 DIMMC1 DIMMD3 DIMMD2 DIMMD1 DIMM C3 DIMM C2...

Страница 36: ...3 SPC 2Gb 4Gb 1DPC 2DPC 1 DPC 2DPC 3DPC 1 5V 1 35V 1 5V 1 35V 1 5V 1 35V 1 5V 1 5V 1 5V 1 35V RDIMM SRx4 4GB 8GB 1600 1333 1600 1333 1333 1333 1333 1066 1066 N A RDIMM DRx4 8GB 16GB 1600 1333 1600 13...

Страница 37: ...3 CPU1 USB6 7 USB2 3 USB4 COM2 CPU4 SLOT8 PCI E 3 0 X8 CPU4 SLOT10 PCI E 3 0 X8 CPU4 SLOT11 PCI E 3 0 X16 CPU3 SLOT7 PCI E 3 0 X8 CPU3 SLOT6 PCI E 3 0 X8 CPU3 SLOT9 PCI E 3 0 X16 CPU2 SLOT5 PCI E 3 0...

Страница 38: ...AN JLAN3 SP1 Internal Speaker T SGPIO 1 2 Serial Link General Purpose I O Headers USB0 1 USB2 3 USB6 7 Front Panel Accessible USB Connections USB4 USB5 Type A Front Panel USB Connectors 4 5 UID UID Sw...

Страница 39: ...igured to function as a suspend button with a setting in the BIOS see Chapter 5 To turn off the power when the system is in suspend mode press the button for 4 seconds or longer Refer to the table on...

Страница 40: ...L1 on the serverboard Attach an appropriate cable from the chassis to be informed of possible chassis intrusion when the chassis is opened Chassis Intrusion Pin Definitions Pin Definition 1 Intrusion...

Страница 41: ...l support See the table on the right for pin definitions Serial COM Ports Pin Definitions Pin Definition Pin Definition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 N A Power LED Speaker...

Страница 42: ...C Enable Jumper JPB1 allows you to enable the BMC controller on the X10QBi A I O module for IPMI KVM support The default setting is Normal Refer to the table on the right for jumper settings BMC Enabl...

Страница 43: ...ight for jumper settings Manufacturer Mode Select Jumper Settings Jumper Setting Definition Pins 1 2 Normal Pins 2 3 Manufacturer Mode Dedicated IPMI LAN LEDs In addition to LAN1 LAN2 a dedicated IPMI...

Страница 44: ...cate the ISO file for your serverboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Another option is...

Страница 45: ...fault User Name and Password for SuperDoctor 5 is admin admin Figure 5 10 SuperDoctor 5 Interface Display Screen Health Information Note The SuperDoctor 5 program and User s Manual can be downloaded f...

Страница 46: ...5 32 SUPERSERVER 8048B TRFT USER S MANUAL Notes...

Страница 47: ...o prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions...

Страница 48: ...o help promote proper airflow for the drive bays As hot swappable components the system may continue running while hard drives are added or replaced to the carriers Removing Hard Drive Carriers from t...

Страница 49: ...e in place to allow proper airflow and prevent overheating Figure 6 4 Accessing the Inside of the System Figure 6 3 Installing a Hard Drive into a Carrier Warning Except for short periods of time swap...

Страница 50: ...chassis and three 8 cm exhaust fans at the rear of the chassis for expelling hot air All fans are hot swappable there is no need to power down the system when replacing fans Replacing a System Fan 1...

Страница 51: ...cord from the failed power supply module 2 Push and hold the release tab on the back of the power supply 3 Grasp the handle and pull the power supply out of its bay 4 Push the replacement power supply...

Страница 52: ...6 10 SUPERSERVER 8048B TRFT USER S MANUAL Notes...

Страница 53: ...ll the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area rese...

Страница 54: ...he manufacturer be liable for direct indirect special incidental or consequential damage arising from a BIOS update If you have to update the BIOS do not shut down or reset the system while the BIOS i...

Страница 55: ...after a power outage Select Stay Off for the system power to remain off after a power outage Select Power On to turn on the system power after a power outage Select Last State to allow the system to r...

Страница 56: ...ble Note Please reboot the system for changes on this setting to take effect Please refer to Intel s web site for detailed information DCU Data Cache Unit Streamer Prefetcher Available when supported...

Страница 57: ...ency The options are Disable and Enable Advanced Power Management Configuration Advanced Power Management Configuration Power Technology Select Energy Efficient to support power saving mode Select Cus...

Страница 58: ...ture is disabled BIOS will set the default value The options are Enable and Disable Short Pwr Power Limit En Enable Select Enable to support Short Duration Power Limit Power Limit 2 The options are En...

Страница 59: ...ptions are GEN1 2 5 GT s GEN2 5 GT s and Auto Override Max Link Width Use this feature to set the link speed for a selected PCI E port to override the maximum link width which was previously set by PC...

Страница 60: ...rrectable error propogation to the II0 core error logic for the port specified by the user The options are Disable and Enable L0s Support When this item is set to Disable II0 will never put its transm...

Страница 61: ...ser to replace the device installed on the port without shutting down the system The options are Disable and Enable PCI E Port Link Select Disable to disable the link that is not involved in training...

Страница 62: ...eset mode for PCI E Gen3 upstream transactions from a slave device to the master device The options are Auto P0 6 0 0 0 dB P1 3 5 0 0 dB P2 4 5 0 0 dB P3 2 5 0 0 dB P4 0 0 0 0 dB P5 0 0 2 0 dB P6 0 0...

Страница 63: ...t Select Enable for Non Iscoh VT d Engine Coherence support to improve system performance The options are Disable and Enable PCI Express Global Options Gen3 Generation 3 Phase3 Loop Count Use this fea...

Страница 64: ...specification The options are Auto 800 1067 1333 1600 1867 and 2133 DDR Voltage Level Select Force to 1 50V to force all DDR3 memory modules to operate at 1 50V Select Force to 1 35V to force all DDR3...

Страница 65: ...y support to increase system performance The options are Disabled and Enabled Data Scrambling Select Enabled to enable data scrambling to enhance system performance and data integrity The options are...

Страница 66: ...Enabled to promote warnings pertaining to RAS Reliability Availability Serviceability issues The options are Enabled and Disabled Memory Test When this feature is set to Enabled memory tests will be p...

Страница 67: ...rroring creates a duplicate copy of the data stored in the memory to enhance data security Sparing This item indicates if memory sparing is supported by the motherboard Memory sparing enhances system...

Страница 68: ...r events before resuming operations The options are 512 1024 1365 1638 1820 1928 2048 2731 3277 3641 4096 5461 6554 8192 10923 16384 32768 Demand Scrub Demand Scrubbing is a process that allows the CP...

Страница 69: ...upport The options are Disabled and Enabled Port 60 64 Emulation Select Enabled for I O port 60h 64h emulation support which will provide complete USB keyboard legacy support for the operating system...

Страница 70: ...et the latency timer of each PCI device installed on a PCI bus Select 64 to set the PCI latency to 64 PCI clock cycles The options are 32 64 96 128 160 192 224 and 248 PCI Bus Clocks VGA Palette Snoop...

Страница 71: ...2 PCI E 3 0 x16 OPROM CPU2 Slot 3 PCI E 3 0 x8 OPROM CPU2 Slot 4 PCI E 3 0 x16 OPROM CPU2 Slot 5 PCI E 3 0 x8 OPROM CPU3 Slot 6 PCI E 3 0 x8 OPROM CPU3 Slot 7 PCI E 3 0 x8 OPROM CPU4 Slot 8 PCI E 3 0...

Страница 72: ...onsole Redirection COM 1 Console Redirection This submenu allows the user to configure the following Console Redirection set tings for this port Console Redirection Select Enabled for Console Redirect...

Страница 73: ...onsole redirection is disabled before booting the OS When set to Always Enable legacy console redirection remains enabled when booting the OS The options are Always Enable and Bootloader Serial Port f...

Страница 74: ...em displays the status of TPM Support to indicate if TPM is currently ac tive or deactivated TPM Owner Status This item displays the status of TPM Ownership iSCSI Configuration This item displays iSCS...

Страница 75: ...stem Administrator Password Use this feature to set the administrator password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters...

Страница 76: ...latile RAM NVRAM Set New DBX Select Yes to confirm that the new DBX files will be downloaded to the Non Volatile RAM NVRAM Append DBX DataBase Timer Select Yes to load the new DBX files from the manuf...

Страница 77: ...is installed in this drive Boot Order 1 USB Hard Disk Drive BBS Priorities Available when a device is installed in this drive Boot Order 1 Network Device BBS Priorities Boot Order 1 UEFI Boot Drive BB...

Страница 78: ...y saved in the system When the dialog box appears asking you if you want to restore user s defaults select Yes to restore the user s defaults previously saved in the system or select No to abandon the...

Страница 79: ...7 52 SUPERSERVER 8048B TRFT USER S MANUAL Notes...

Страница 80: ...r for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error X...

Страница 81: ...A 2 SUPERSERVER 8048B TRFT USER S MANUAL Notes...

Страница 82: ...ry of 6 TB of DDR3 1600 1333 1066 800 ECC RDIMM LDIMM memory Note refer to Section 5 5 for details on installation Note Check the Supermicro website www supermicro com for the latest memory support in...

Страница 83: ...onment Operating Temperature 10 to 35 C 50 to 95 F Non operating Temperature 40 to 70 C 40 to 158 F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non conde...

Страница 84: ...rform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such pr...