Installer / Service Manual BURNiT PM Comfort
Plus
30 –ЕN
T17
Delay time Combustion Power
Change
0
900
[s]
10
10
T18
Delay time Combustion Power
Change in exit from Ignition
0
900
[s]
10
10
T22
Delay time for Standby Input
0
900
[s]
10
10
T24
Length signalling of fuel lack
0
3600
[s]
180
180
T41
Work time of Pump
0
3600
[s]
30
30
T42
Maximum time of inactivity of
Pump
1
9600
[ore]
60
60
T43
Time, after which the stove goes
from Modulation to Standby if
Water Temperature> [Boiler
Thermostat t+d23] and A13= 1
0
9600
[s]
60
60
6.7.5. Enable’s Menu
TP O8
Code
Description
Min.
Max.
U
Def.
A01
За P26=0
0
Reached the Room Thermostat the
stove goes in Extinguishing
0
3
[nr]
2
1
Reached the Room Thermostat the
stove goes in Modulation
2
Reached the Room Thermostat the
stove goes in Standby
3
Reached the Room Thermostat the
system blocks the Pump until water
temperature < Th21
A06
0
In Modulation the system uses
Power 1: C03,U03
0
1
[nr]
0
1
In Modulation the system uses
Modulation Power: C11,U11
A07
0
The input AUX is used for ON/OFF
functioning
0
3
[nr]
0
1
The input AUX is used for
Modulation/Normal functioning
2
The input AUX is used for
Standby/Normal functioning
3
The input AUX is used to block the
Pump until water temperature <
Th21 ( P26=0 )
A13
0
Reached the Boiler Thermostat the
stove goes in Modulation
0
1
[nr]
1