Installer / Service Manual BURNiT PM Comfort
Plus
31 –ЕN
1
Reached the Boiler Thermostat the
stove goes in Modulation, then if
d23 is satisfied and T43 is finished it
goes in Standby
A14
0
Error Sensor Pressure disabled
0
1
[nr]
0
1
Error Sensor Pressure enabled
A19
0
Room Thermostat ON/OFF selected
0
1
[nr]
1
1
Room Probe selected
А26
0
The immediate Exit from StandBy is
allowed
0
1
[nr]
0
1
Exit from Standby is allowed
>after the timer T13 and
> if the Exhausting
Temperature<Th28
A28
0
Auger brake not activated
0
1
[nr]
0
1
Auger brake activated
A50
0
Modem Management disabled
0
1
[nr]
0
1
Modem Management enabled
P02
Maximum number ignition attempts
1
5
[nr]
1
P03
Work Combustion Powers’ number
1
5
[nr]
5
P09
Pellet Sensor configuration:
0
1
[nr]
0
P20
Configuration of Pressure Boiler Water
Sensor
0
2
[nr]
0
P26
Plumbing system management
0
1
[nr]
0
6.7.6. Outputs Menu Test
TP 12
It allows the test of the single management outputs with the connected devices. The
function is available in
OFF
state.
Code
Description
Min.
Max.
U
Def.
To01
Auger Test
OFF
ON
-
To03
Combustion Fan Test
0
230
[Volt]
300
2800
[RPM]
During Combustion Fan Test, upper display shows the set value [Volt] [RPM],
bottom display shows the RPM of the fan detected by the encoder if is present: so it is possible
to create a conversion table [RPM] / [Volt] to use for the passage from encoder Mode
P25=1
to not encoder Mode
P25=0
in case of encoder breakage.
To04
Igniter Resistance Test
OFF
ON
-
To05
Pump Test
OFF
ON
-