Installer / Service Manual BURNiT PM Comfort
Plus
39 –ЕN
Start
To start
Ignition
from stove OFF.
The Modem sends back a message to the number from which it
received the command with a status and a possible alarm error code
Stop
To start
Extinguishing
from stove ON.
The Modem sends back a message to the number from which it
received the command with a status and a possible alarm error code.
Status
To ask the stove’s
State.
The Modem sends back a message to the number from which it
received the command with a status and a possible alarm error code.
Learn
To
Learn
the number to send an SMS in case of Block.
If there is a Block condition, the Modem automatically sends a
message to the learnt number with the stove’s state and the alarm
error code.
6.9.2. Supply Voltage Lack Management
In case of Supply Voltage lack, the system saves the most important functioning data.
With the return of the Supply Voltage, the system evaluates the saved data and:
• If the stove were ON and the Exhausting Temperature more than
Th06+d01
the system goes in
Recover Ignition
.
Pushing the button P1 it is possible the sudden new system’s Ignition.
• If the stove were ON but the Exhausting Temperature is less than
Th06+d01
the system goes in Extinguishing with error
Er15
.
• If the stove were OFF, or in Extinguishing or Block, the system returns in the
previous state.
• In case of prolonged absence of Supply Voltage (about one week) the systems
goes in BLOCK
with error message
Er11
to indicate not correct DAY and
TIME value.
After the reset by the button P1, the
Time
value blinks signalling the need to set
the right Time
6.9.3. Combustion power change delay Management
When the system exits from the Ignition and goes in Normal, the Combustion Power,
starting from the Combustion.
Power 1, reaches the target one increasing the value with the delay time as the timer
T18.
The other manual or automatic power changes are managed and actuated with the
delay time as timer
T17
.