3.7. Roof installation of exhaust gas pipe
The upper part of the pipe (chimney) is dеsigned for the proper outlet of the exhaust
gases in the atmosphere. The tube must be protected from rain, snow and all
objects, and to ensure discharging of exhaust gases in the atmosphere under windy
conditions.
Requirements for the upper part of the tube:
•
The inner part must not be less than the one on the pellet stove;
•
The outer part of the pipe to be insulated;
•
The authorized installer must protect the system from rain, snow and winter.
•
Easy dismounting for cleaning;
•
The type of the tube must be such that fits in the aesthetic appearance of the
building;
•
Not to be close to obstacles and other chimneys.
The distance between the tube and other obstacles (walls, trees and others) must
not to be less than 10 m. If the distance is less than 10m the height of the tubes must
be 1m above the obstacles (walls, trees, etc.).
If there are other chimneys – the exhaust gases pipe must be at distance no less than
2m from it.
We recommend the exhaust gases pipe to be at least 1m above the roof.
Problems with exhaust gases
Among all the atmosphere influences on the system the wind matters most.
3.8. Connection to the power supply
Once the pellet stove is installed in the room it must be connected to the power
supply. The power cable is situated at the back part of the pellet stove. Check the
condition of the cable. If any damages are noticed notify an authorized service for
exchange.
Before connecting the pellet stove to the power supply check carefully:
•
Whether the characteristics of the electrical supply match the requirements
indicated on the label of the pellet stove.