Installer / Service Manual BURNiT PM Comfort
Plus
21 –ЕN
6.5. User Menu (1)
6.5.1. Ignition / Extinguishing
The Ignition and the Extinguishing are
activated with a long pushing of the button
P1.
The Ignition is signaled by the first blinking
than fix led
L1
.
The Work state is signaled by the fix led
L4.
The Modulation state is signaled by the
blinking
L4.
The Extinguishing is signaled by the blinking
led
L3
.
The Extinguishing finished =OFF state is signaled by the fix led
L3.
6.5.2. Combustion Power Setting
Click button
P2:
the display
D2
blinks.
With other click of the button
P2
the power
is changed according to the values.
Example:
1 – 2 – 3 – 4 – 5 – A
(
A
= Automatic Combustion)
After 3 seconds the new value is
memorised and the display shows as
normal.
6.5.3. Work Thermostat Setting
Click button
P3
or
P4
: the display
D3
blinks.
With other click of the buttons
P3 / P4
the
value of the thermostat is increased or
decreased.
After 3 seconds the new value is
memorised and switches to the current
value of stove temperature.